Safe Percutaneous Dilatational Tracheostomy Using a Pre‐Measured Light‐Guided Endotracheal Tube Withdrawal Technique: A Case Report
Respirology Case Reports · 2026-06 · 14 (6)
DOI: 10.1002/rcr2.70637 ↗Kurz gefasst
Fallbericht in der Zeitschrift Respirology Case Reports, online erschienen am 28.05.2026. Verfasst von Yuya Aoki und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Intensive Care, Department of Emergency and Disaster Medicine Kashiwa Hospital, the Jikei University School of Medicine Kashiwa Chiba Jap…. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Percutaneous dilatational tracheostomy (PDT) is a bedside procedure for patients requiring prolonged mechanical ventilation. Although its overall safety is comparable to that of surgical tracheostomy, complications related to endotracheal tube (ETT) manipulation remain a concern. In this report, we describe a simple, reproducible two‐step approach for ETT repositioning during PDT that (1) pre‐measures an individualized withdrawal distance using bronchoscopic illumination and (2) confirms final positioning in real time by transillumination at the incision site in a patient requiring tracheostomy after prolonged mechanical ventilation. The procedure was completed within 20 min without complications. This technique may facilitate safer ETT repositioning during PDT.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Intensive Care, Department of Emergency and Disaster Medicine Kashiwa Hospital, the Jikei University School of Medicine Kashiwa Chiba Japan.
ORCID-Profile: Takuo Yoshida
Zitieren
APA
Aoki, Y., Kono, M., & Yoshida, T. (2026). Safe Percutaneous Dilatational Tracheostomy Using a Pre‐Measured Light‐Guided Endotracheal Tube Withdrawal Technique: A Case Report. Respirology Case Reports, 14(6). https://doi.org/10.1002/rcr2.70637
Vancouver
Aoki Y, Kono M, Yoshida T. Safe Percutaneous Dilatational Tracheostomy Using a Pre‐Measured Light‐Guided Endotracheal Tube Withdrawal Technique: A Case Report. Respirology Case Reports. 2026;14(6). doi:10.1002/rcr2.70637