EUVIMEDEUVIMED entdecken
Crossref

Identification and characterization of alkaline hydrolytic degradation products of ivacaftor by UPLC‐PDA and UPLC‐ESI‐QTOF‐MS techniques

Aastha Bishnoi, Alka Bali iD, Akshay Kumar

Rapid Communications in Mass Spectrometry · 15.01.2025 · 39 (1)

DOI: 10.1002/rcm.9930 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 30.10.2024. Verfasst von Aastha Bishnoi und 2 weiteren Autor:innen. Beteiligte Einrichtung: University Institute of Pharmaceutical Sciences, UGC Center of Advanced Study, Panjab University, Chandigarh, India. Hauptthemen laut MEDLINE: Aminophenols, Quinolones, Spectrometry, Mass, Electrospray Ionization, Drug Stability. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: University Grants Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

The study of inherent stability characteristics of drugs has been advocated to be important by various regulatory agencies like the ICH, USFDA, and others. The current work was envisaged to investigate the forced degradation profile of the drug ivacaftor under ICH‐prescribed stress conditions, identification of its potential degradants, and postulation of the degradation routes for their generation.

Methods

The stress degradation studies were performed on the drug as per the ICH guideline Q1A(R2). A UPLC‐photodiode array‐based chromatographic method was developed to satisfactorily resolve the drug from its degradation products, validated in accordance with various ICH prescribed parameters, and assessed for its BAGI practicality index. The degradation products were identified and characterized by UPLC‐ESI‐QTOF‐MS studies.

Results

The drug was found to significantly degrade under conditions of alkaline hydrolytic stress and it was found to be stable under all other stressor environments including acid/neutral hydrolytic, photolytic, thermal, and oxidative stress. Four alkaline hydrolytic degradation products (I‐IV) were revealed by UPLC‐QTOF‐MS studies which were well‐resolved from the drug over a C18 UPLC column by the developed UPLC‐PDA method. The detection wavelength was selected as 310 nm. Characterization of the four degradation products (I–IV) was carried out by their mass spectral data and their respective degradation routes were elucidated.

Conclusions

A UPLC‐PDA method was developed and validated for ivacaftor and its practicality BAGI index was computed. Four alkaline hydrolytic degradation products of ivacaftor were revealed through UPLC‐ESI‐QTOF‐MS studies and corresponding degradation routes were elucidated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AminophenolsQuinolonesSpectrometry, Mass, Electrospray IonizationDrug StabilityChromatography, High Pressure LiquidHydrolysisHydrogen-Ion ConcentrationReproducibility of Results

Substanzen

AminophenolsQuinolonesivacaftor

Autor:innen und Institutionen

  • University Institute of Pharmaceutical Sciences, UGC Center of Advanced Study, Panjab University, Chandigarh, India.

ORCID-Profile: Alka Bali

Förderung

  • University Grants Commission

Zitieren

APA

Bishnoi, A., Bali, A., & Kumar, A. (2025). Identification and characterization of alkaline hydrolytic degradation products of ivacaftor by UPLC‐PDA and UPLC‐ESI‐QTOF‐MS techniques. Rapid Communications in Mass Spectrometry, 39(1). https://doi.org/10.1002/rcm.9930

Vancouver

Bishnoi A, Bali A, Kumar A. Identification and characterization of alkaline hydrolytic degradation products of ivacaftor by UPLC‐PDA and UPLC‐ESI‐QTOF‐MS techniques. Rapid Communications in Mass Spectrometry. 2025;39(1). doi:10.1002/rcm.9930

BibTeX
@article{Bishnoi2025,
  author = {Bishnoi, Aastha and Bali, Alka and Kumar, Akshay},
  title = {Identification and characterization of alkaline hydrolytic degradation products of ivacaftor by UPLC‐PDA and UPLC‐ESI‐QTOF‐MS techniques},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2025},
  volume = {39},
  number = {1},
  doi = {10.1002/rcm.9930}
}
Kostenlos starten →