EUVIMEDEUVIMED entdecken
Crossref

Analysis of the polymeric mixture in hypoxen, using high‐performance liquid chromatography coupled with high‐resolution mass spectrometry

Abdul Khader Karakka Kal iD, Michael Benedict Subhahar iD, Moses Philip, Tajudheen K Karatt iD

Rapid Communications in Mass Spectrometry · 2024

DOI: 10.1002/rcm.9918 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2024. Verfasst von Abdul Khader Karakka Kal und 3 weiteren Autor:innen. Beteiligte Einrichtung: Equine Forensic Unit, Central Veterinary Research Laboratory, Dubai, United Arab Emirates. Hauptthemen laut MEDLINE: Doping in Sports. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Hypoxen is a medication known for providing individuals with a “second wind,” by lowering the threshold for muscle fatigue and enhancing the body's efficiency under challenging conditions. Athletes who have used this medication report enhanced training outcomes and increased physical endurance. It is crucial to emphasize that hypoxen is not categorized as a prohibited substance as yet and is thus assumed safe for use in competitive sports. However, the polymeric nature of hypoxen presents challenges in detection and identification.

Methods

To prevent the potential misuse of this substance as a doping agent, doping control laboratories must therefore develop a detection method. This study aimed to address this gap by developing a comprehensive detection method for the polymeric mixtures within hypoxen, employing liquid chromatography‐electrospray ionization‐mass spectrometry.

Results

Among the different columns tested, the Accucore and Syncronis HILIC columns demonstrated exceptional performance, yielding excellent separation with high‐quality results. The study found that the hypoxen consisted of between 1 and 6 repetitions of 2,4‐dihydroxyphenylene units. It was crucial to highlight that each unit contained multiple isomers due to the incorporation of the sulfonic acid group at both the ‐SH and ‐OH positions.

Conclusions

The results of this study will significantly contribute to the precise identification of hypoxen use, thereby aiding in the scrutiny of its abuse in competitive sports.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Doping in SportsChromatography, High Pressure LiquidSpectrometry, Mass, Electrospray IonizationPolymersHumansSubstance Abuse DetectionMass Spectrometry

Substanzen

Polymers

Autor:innen und Institutionen

  • Equine Forensic Unit, Central Veterinary Research Laboratory, Dubai, United Arab Emirates.

ORCID-Profile: Abdul Khader Karakka Kal, Michael Benedict Subhahar, Tajudheen K Karatt

Zitieren

APA

Karakka Kal, A. K., Subhahar, M. B., Philip, M., & Karatt, T. K. (2024). Analysis of the polymeric mixture in hypoxen, using high‐performance liquid chromatography coupled with high‐resolution mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9918

Vancouver

Karakka Kal AK, Subhahar MB, Philip M, Karatt TK. Analysis of the polymeric mixture in hypoxen, using high‐performance liquid chromatography coupled with high‐resolution mass spectrometry. Rapid Communications in Mass Spectrometry. 2024. doi:10.1002/rcm.9918

BibTeX
@article{KarakkaKal2024,
  author = {Karakka Kal, Abdul Khader and Subhahar, Michael Benedict and Philip, Moses and Karatt, Tajudheen K},
  title = {Analysis of the polymeric mixture in hypoxen, using high‐performance liquid chromatography coupled with high‐resolution mass spectrometry},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2024},
  doi = {10.1002/rcm.9918}
}
Kostenlos starten →