Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube
Rapid Communications in Mass Spectrometry · 30.07.2024 · 38 (14)
DOI: 10.1002/rcm.9767 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 15.05.2024. Verfasst von Maroua Omezzine Gnioua und 2 weiteren Autor:innen. Beteiligte Einrichtung: J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, Czechia. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Akademie Věd České Republiky (Czech Academy of Sciences), Grantová Agentura České Republiky (Czech Science Foundation).
Themen: Mobilisation
Abstract (Originalsprache)
Rationale
In soft chemical ionization mass spectrometry, analyte ions are produced via ion–molecule reactions in the reactor. When an electric field E is imposed, the ion drift velocity v d determines the reaction time and the effective ion temperature. Agreement between experimental ion mobilities and theoretical predictions confirms the accuracy of the ion residence time measurement procedure.
Methods
A selected ion flow‐drift tube (SIFDT), an instrument with a chemical ionization source, was used to produce protonated aldehydes and selectively inject them into the resistive glass drift tube filled with He. Arrival‐time distributions of ions were obtained using the Hadamard modulation. Reduced ion mobilities were then obtained at a pressure of 2 hPa in the E / N range of 5–15 Td. Theoretical ion mobility values were calculated using two methods: hard‐sphere approximation and trajectory modelling.
Results
The measured mobilities of three saturated and three unsaturated protonated aldehydes do not show substantial variation across the studied E / N range. Effective temperatures calculated using the Wannier formula from measured gas temperatures ranged from 300 to 315 K. Experimentally obtained values of the near‐zero‐ E / N‐ reduced ion mobilities agree with both methods of calculations typically within ±3% standard deviation (maximum ±5%).
Conclusions
The experimental SIFDT values of reduced mobilities in He of protonated aldehyde molecules generated from a chemical ionization source are in close agreement with two different theoretical methods based on the density functional theory calculations of ion geometries and partial atomic charges. Besides its fundamental importance, the ion mobility results validate the correct operation of the drift tube reactor and the ion residence time measurement procedure. Diffusion losses can also be determined from these results.
Autor:innen und Institutionen
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, Czechia.
- Department of Surface and Plasma Science, Faculty of Mathematics and Physics, Charles University Prague, Prague, Czechia.
ORCID-Profile: Anatolii Spesyvyi
Förderung
- Akademie Věd České Republiky (Czech Academy of Sciences)
- Grantová Agentura České Republiky (Czech Science Foundation)
Zitieren
APA
Gnioua, M. O., Španěl, P., & Spesyvyi, A. (2024). Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube. Rapid Communications in Mass Spectrometry, 38(14). https://doi.org/10.1002/rcm.9767
Vancouver
Gnioua MO, Španěl P, Spesyvyi A. Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube. Rapid Communications in Mass Spectrometry. 2024;38(14). doi:10.1002/rcm.9767
BibTeX
@article{Gnioua2024,
author = {Gnioua, Maroua Omezzine and Španěl, Patrik and Spesyvyi, Anatolii},
title = {Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube},
journal = {Rapid Communications in Mass Spectrometry},
year = {2024},
volume = {38},
number = {14},
doi = {10.1002/rcm.9767}
}
EUVIMED