Rapid and simple identification of trace amounts of sodium azide in beverages and bodily fluids followed by derivatization and liquid chromatography–electrospray ionization tandem mass spectrometry
Rapid Communications in Mass Spectrometry · 15.11.2023 · 37 (21)
DOI: 10.1002/rcm.9624 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 07.09.2023. Verfasst von Hagit Prihed und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Israel Institute for Biological Research (IIBR), Ness Ziona, Israel. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Rationale
Sodium azide (NaN 3 ) is a toxic chemical agent to humans by ingestion and inhalation with a growing number of intentional exposures and accidental cases over the last few decades. Due to its low molecular weight and lack of any chromophore, its retention and detection by reverse‐phase liquid chromatography–ultraviolet–mass spectrometry methods are a challenging task.
Methods
To be able to confirm azide exposure, we have developed a method to identify azide in both beverages and bodily fluids. The identification of azide (N 3 − ) is based on derivatization with N ‐(2‐(bromomethyl)benzyl)‐ N , N ‐diethylethanaminium bromide (CAX‐B) at 25°C for 15 min followed by LC/ESI‐MS/MS analysis, with no other sample preparation.
Results
The azide after derivatization (CAX‐N 3 ) was stable, retainable by LC and sensitively detected by selected reaction monitoring. The ESI‐MS/MS fragmentation of the M + precursor ion produced characteristic product ions at m / z 118, 100, 91 and 86. The calibration curves for CAX‐N 3 showed linearity over two orders of magnitude with R 2 value of 0.99. Low limits of identification of 0.1–0.5 ng/mL were obtained in all investigated matrices (drinking water, tea, orange juice, plasma and urine).
Conclusions
Compared with previously reported chromatography‐based methods, this method that was based on derivatization and LC/ESI‐MS/MS analysis was substantially more sensitive, simpler and faster. The method can be used for forensic investigation to confirm azide exposure from fatal use to much smaller intoxication dose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, Israel Institute for Biological Research (IIBR), Ness Ziona, Israel.
ORCID-Profile: Avi Weissberg
Zitieren
APA
Prihed, H., Shifrovitch, A., Shamai Yamin, T., Madmon, M., Belay, C., Blanca, M., & Weissberg, A. (2023). Rapid and simple identification of trace amounts of sodium azide in beverages and bodily fluids followed by derivatization and liquid chromatography–electrospray ionization tandem mass spectrometry. Rapid Communications in Mass Spectrometry, 37(21). https://doi.org/10.1002/rcm.9624
Vancouver
Prihed H, Shifrovitch A, Shamai Yamin T, Madmon M, Belay C, Blanca M, et al. Rapid and simple identification of trace amounts of sodium azide in beverages and bodily fluids followed by derivatization and liquid chromatography–electrospray ionization tandem mass spectrometry. Rapid Communications in Mass Spectrometry. 2023;37(21). doi:10.1002/rcm.9624
BibTeX
@article{Prihed2023,
author = {Prihed, Hagit and Shifrovitch, Avital and Shamai Yamin, Tamar and Madmon, Moran and Belay, Chen and Blanca, Merav and Weissberg, Avi},
title = {Rapid and simple identification of trace amounts of sodium azide in beverages and bodily fluids followed by derivatization and liquid chromatography–electrospray ionization tandem mass spectrometry},
journal = {Rapid Communications in Mass Spectrometry},
year = {2023},
volume = {37},
number = {21},
doi = {10.1002/rcm.9624}
}
EUVIMED