Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 23.12.2022. Verfasst von Satoka Aoyagi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Science and Technology, Seikei University, Tokyo, Japan. Hauptthemen laut MEDLINE: Spectrometry, Mass, Secondary Ion, Organic Chemicals. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science (JSPS) KAKENHI, grant no, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Matrix effects cause a nonlinear relationship between ion intensities and concentrations in mass spectrometry, including time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). Here, two artificial neural network (ANN)‐based methods, autoencoder‐based and simple ANN methods, were employed for the quantitative and qualitative analyses of a two organic compound mixture via ToF‐SIMS.

Methods

The multilayer model sample contained a mixture of Irganox 1010 and Fmoc‐pentafluoro‐L‐phenylalanine (Fmoc‐PFLPA). The sample's positive and negative ion depth profiles were collected through ToF‐SIMS. ToF‐SIMS‐derived cross‐sectional image datasets were analyzed using three unsupervised methods, namely principal component analysis (PCA), multivariate curve resolution (MCR), and use of a sparse autoencoder (SAE). The supervised simple ANN method was optimized based on the spectra and validated by predicting the test dataset ratios of Irganox 1010.

Results

The results obtained using the SAE demonstrated linear calibration curves and appropriate material distribution images. The Irganox 1010 and Fmoc‐PFLPA positive and negative ion datasets exhibited >0.97 correlation coefficients. The PCA and MCR results demonstrated lower linearity than that of SAE. Moreover, SAE weights indicated the ions important for each organic compound. The simple ANN method accurately predicted the ratios in the test dataset and indicated the important ions.

Conclusions

Both the supervised and unsupervised methods based on ANN, which were employed in regulating nonlinear relationships, were effective in the quantitative and qualitative analyses of the ToF‐SIMS data of the two organic compound mixtures. Regarding qualitative analysis, both ANN‐based methods indicated specific ions from the molecules in the sample.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, Mass, Secondary IonOrganic ChemicalsNeural Networks, ComputerButylated Hydroxytoluene

Substanzen

Irganox 1010Organic ChemicalsButylated Hydroxytoluene

Autor:innen und Institutionen

  • Faculty of Science and Technology, Seikei University, Tokyo, Japan.
  • Surface Science Laboratories, Toray Research Center, Inc., Otsu, Shiga, Japan.

ORCID-Profile: Satoka Aoyagi

Förderung

  • Japan Society for the Promotion of Science (JSPS) KAKENHI, grant no
  • Japan Society for the Promotion of Science

Zitieren

APA

Aoyagi, S., & Matsuda, K. (2023). Quantitative analysis of ToF‐SIMS data of a two organic compound mixture using an autoencoder and simple artificial neural networks. Rapid Communications in Mass Spectrometry, 37(4). https://doi.org/10.1002/rcm.9445

Vancouver

Aoyagi S, Matsuda K. Quantitative analysis of ToF‐SIMS data of a two organic compound mixture using an autoencoder and simple artificial neural networks. Rapid Communications in Mass Spectrometry. 2023;37(4). doi:10.1002/rcm.9445

BibTeX
@article{Aoyagi2023,
  author = {Aoyagi, Satoka and Matsuda, Kazuhiro},
  title = {Quantitative analysis of ToF‐SIMS data of a two organic compound mixture using an autoencoder and simple artificial neural networks},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2023},
  volume = {37},
  number = {4},
  doi = {10.1002/rcm.9445}
}
Kostenlos starten →