Measurement of tigecycline in dried blood spots by LC–MS/MS and comparison tigecycline concentrations between whole blood and plasma
Rapid Communications in Mass Spectrometry · 2023
DOI: 10.1002/rcm.9416 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2023. Verfasst von Yan Yan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Dried Blood Spot Testing. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Scientific and Technological Foundation of Shaanxi Province.
Abstract (Originalsprache)
Rationale
An LC–MS/MS method was established to measure tigecycline in dried blood spots (DBSs).
Methods
The DBS specimens obtained by applying 30 μl of blood to filter paper were extracted with hydrogen oxide and subsequently precipitated protein with perchloric acid, then the extract was directly analyzed by liquid chromatography tandem mass spectrometry. A Hypersil GOLD aQ column was utilized for separating the analytes, and detection was carried out in positive and selective reaction monitoring modes. The precursors to product ion transitions m / z 586.3 → 513.1 and m / z 586.3 → 569.2 were monitored for tigecycline, and m / z 473.2 → 456.0 and m/z 473.2 → 367.0 for 9‐amino minocycline as internal standard.
Results
The validation parameters of specificity and selectivity, linearity (0.02–5 μg ml −1 ), sensitivity (limit of quantification 0.02 μg ml −1 ), intra‐ and interday precision (within 15%) and relative error (within ±15%) were acceptable. The recoveries were from 84.65% to 90.49% and from 85.41% to 95.72% for tigecycline and internal standard, respectively, and the matrix effect was not evident to influence accuracy. The impact of hematocrit on measurement of the analyte was negligible, and after preserving at ambient temperature for 24 h and at 4°C for 1 month it remained steady.
Conclusions
The advantages of nonintrusive blood collection and micro‐volume sample requirements make DBS a potent surrogate to conventional venepuncture for sampling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Pharmacy, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
- Department of Clinical Laboratory, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
ORCID-Profile: Xiaoliang Cheng
Förderung
- National Natural Science Foundation of China
- Scientific and Technological Foundation of Shaanxi Province
Zitieren
APA
Yan, Y., Qu, J., Di, Y., Zhang, C., & Cheng, X. (2023). Measurement of tigecycline in dried blood spots by LC–MS/MS and comparison tigecycline concentrations between whole blood and plasma. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9416
Vancouver
Yan Y, Qu J, Di Y, Zhang C, Cheng X. Measurement of tigecycline in dried blood spots by LC–MS/MS and comparison tigecycline concentrations between whole blood and plasma. Rapid Communications in Mass Spectrometry. 2023. doi:10.1002/rcm.9416
BibTeX
@article{Yan2023,
author = {Yan, Yan and Qu, Jie and Di, Ying and Zhang, Chun and Cheng, Xiaoliang},
title = {Measurement of tigecycline in dried blood spots by LC–MS/MS and comparison tigecycline concentrations between whole blood and plasma},
journal = {Rapid Communications in Mass Spectrometry},
year = {2023},
doi = {10.1002/rcm.9416}
}
EUVIMED