EUVIMEDEUVIMED entdecken
Crossref

Rapid Screening of New Psychoactive Substances in Paper‐Based Prison Correspondence via TEIS‐TQMS

Paulina Pióro iD, Wiktor Kasprzyk, Bartłomiej Feigel iD

Rapid Communications in Mass Spectrometry · 30.01.2027 · 41 (2)

DOI: 10.1002/rcm.70206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 16.11.2026. Verfasst von Paulina Pióro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology and Physical Chemistry, Cracow University of Technology, Krakow, Poland. Hauptthemen laut MEDLINE: Psychotropic Drugs, Mass Spectrometry. Die Arbeit nennt 18 Literaturangaben. Gefördert von: National Centre for Research and Development, Poland, Jan Sehn Institute of Forensic Research, Narodowe Centrum Badań i Rozwoju.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

New psychoactive substances (NPS) are rapidly evolving synthetic compounds designed to mimic controlled drugs while evading legal regulation. Their increasing presence on impregnated paper materials in correctional and forensic settings creates a need for rapid, selective methods to detect trace quantities in complex matrices, as conventional solvent‐based extraction workflows are often too slow for forensic screening.

Methods

Thermal Extraction Ion Source coupled with Triple Quadrupole Mass Spectrometry (TEIS‐TQMS) was evaluated for qualitative analysis of selected NPS spanning different chemical classes. The approach enables direct surface analysis of impregnated materials with minimal sample preparation. Method development included optimization of thermal extraction and ionization parameters, followed by assessment of validation criteria including matrix effects, precision, and limit of detection.

Results

All analytes were detected with 100% reliability across 10 replicates on every substrate, despite substrate‐dependent signal variability (%CV up to 236%). Matrix effects ranged from strong ion suppression (up to 87%) to marked enhancement (up to −2081%), particularly for the synthetic cannabinoid. Limits of detection ranged from 0.05 to 16.13 μg/mL depending on compound, transition, and substrate, confirming the method's suitability for qualitative screening.

Conclusions

TEIS‐TQMS offers a fast, low‐sample‐handling alternative to conventional methods for detecting NPS on complex surfaces such as impregnated paper. This direct ambient mass spectrometric approach may support the development of more efficient analytical protocols for forensic toxicology and monitoring of emerging psychoactive substances.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Psychotropic DrugsMass SpectrometryPaperLimit of DetectionReproducibility of ResultsPrisonsHumansIllicit Drugs

Stichwörter der Autor:innen

TEIS‐TQMSnew psychoactive substances (NPS)paper matrixprison correspondencerapid screening

Substanzen

Psychotropic DrugsIllicit Drugs

Autor:innen und Institutionen

  • Department of Biotechnology and Physical Chemistry, Cracow University of Technology, Krakow, Poland.
  • Jan Sehn Institute of Forensic Research, Krakow, Poland.

ORCID-Profile: Paulina Pióro, Bartłomiej Feigel

Förderung

  • National Centre for Research and Development, Poland
  • Jan Sehn Institute of Forensic Research
  • Narodowe Centrum Badań i Rozwoju

Zitieren

APA

Pióro, P., Kasprzyk, W., & Feigel, B. (2027). Rapid Screening of New Psychoactive Substances in Paper‐Based Prison Correspondence via TEIS‐TQMS. Rapid Communications in Mass Spectrometry, 41(2). https://doi.org/10.1002/rcm.70206

Vancouver

Pióro P, Kasprzyk W, Feigel B. Rapid Screening of New Psychoactive Substances in Paper‐Based Prison Correspondence via TEIS‐TQMS. Rapid Communications in Mass Spectrometry. 2027;41(2). doi:10.1002/rcm.70206

BibTeX
@article{Piro2027,
  author = {Pióro, Paulina and Kasprzyk, Wiktor and Feigel, Bartłomiej},
  title = {Rapid Screening of New Psychoactive Substances in Paper‐Based Prison Correspondence via TEIS‐TQMS},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2027},
  volume = {41},
  number = {2},
  doi = {10.1002/rcm.70206}
}
Kostenlos starten →