Systematic Optimization of an SLE‐DAPTAD LC–MS/MS Workflow for Simultaneous Quantification of Low‐Abundance Vitamin D 3 Metabolites in Plasma
Rapid Communications in Mass Spectrometry · 2026
DOI: 10.1002/rcm.70158 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2026. Verfasst von Marzieh Amirmostofian und 3 weiteren Autor:innen. Beteiligte Einrichtung: Mass Spectrometry and Proteomics, College of Health, School of Pharmacy and Biomedical Science, Adelaide University, Adelaide, South Australia, Austr…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Cholecalciferol. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Rationale
Liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis of vitamin D 3 metabolites is analytically challenging because these compounds are structurally similar, strongly matrix‐associated, and have poor ionization efficiency. These limitations are particularly important for low‐abundance metabolites such as 1,25(OH) 2 D 3 . This study systematically compared extraction and derivatization strategies to develop a simplified workflow for simultaneous quantification of 25(OH)D 3 , 3‐epi‐25(OH)D 3 , 1,25(OH) 2 D 3 , and 24,25(OH) 2 D 3 in plasma.
Methods
Five sample‐preparation approaches—simple protein precipitation, liquid–liquid extraction, salting‐out assisted liquid–liquid extraction, solid‐phase extraction, and supported liquid extraction—were evaluated under comparable conditions. Two derivatization reagents, 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) and 2‐fluoro‐1‐methylpyridinium‐ p ‐toluenesulfonate (FMP‐TS), were compared. The selected workflow was validated according to bioanalytical method validation criteria.
Results
Supported liquid extraction using ethyl acetate/methyl tert‐butyl ether (1:1, v/v) provided the best overall balance of signal intensity, reproducibility, simplicity, and suitability for high‐throughput processing. DAPTAD derivatization produced a substantially higher MS response than FMP‐TS and was selected for the final method. The optimized SLE‐DAPTAD LC–MS/MS workflow showed good linearity ( r 2 > 0.99), acceptable accuracy and precision, recovery of 72.5%–104%, and limits of quantification of 0.08 ng/mL for 3‐epi‐25(OH)D 3 , 1,25(OH) 2 D 3 , and 24,25(OH) 2 D 3 , and 0.88 ng/mL for 25(OH)D 3 .
Conclusions
The optimized SLE‐DAPTAD LC–MS/MS workflow provides a simple, sensitive, and automation‐compatible approach for simultaneous quantification of four vitamin D 3 metabolites in plasma. The method is positioned as an analytical workflow for method development and low‐volume plasma analysis, rather than as a fully standardized routine diagnostic assay for endogenous 1,25(OH) 2 D 3 measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Mass Spectrometry and Proteomics, College of Health, School of Pharmacy and Biomedical Science, Adelaide University, Adelaide, South Australia, Australia.
- College of Health, School of Pharmacy and Biomedical Science, Adelaide University, Adelaide, South Australia, Australia.
ORCID-Profile: Marzieh Amirmostofian, Peter Hoffmann
Zitieren
APA
Amirmostofian, M., Wiese, M. D., Anderson, P. H., & Hoffmann, P. (2026). Systematic Optimization of an SLE‐DAPTAD LC–MS/MS Workflow for Simultaneous Quantification of Low‐Abundance Vitamin D 3 Metabolites in Plasma. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.70158
Vancouver
Amirmostofian M, Wiese MD, Anderson PH, Hoffmann P. Systematic Optimization of an SLE‐DAPTAD LC–MS/MS Workflow for Simultaneous Quantification of Low‐Abundance Vitamin D 3 Metabolites in Plasma. Rapid Communications in Mass Spectrometry. 2026. doi:10.1002/rcm.70158
BibTeX
@article{Amirmostofian2026,
author = {Amirmostofian, Marzieh and Wiese, Michael D and Anderson, Paul H and Hoffmann, Peter},
title = {Systematic Optimization of an SLE‐DAPTAD LC–MS/MS Workflow for Simultaneous Quantification of Low‐Abundance Vitamin D 3 Metabolites in Plasma},
journal = {Rapid Communications in Mass Spectrometry},
year = {2026},
doi = {10.1002/rcm.70158}
}
EUVIMED