Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 14.06.2026. Verfasst von Madison Pursell und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, West Virginia University, Morgantown, West Virginia, USA. Hauptthemen laut MEDLINE: Metabolomics, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

The varied properties of metabolomics components dictate the tools used in mass spectrometry (MS) characterization including the selection of the ionization source. However, the ionization of select compounds limits characterization efficiency. A simple setup employing vibrating sharp‐edge spray ionization (VSSI) accesses two distinct ionization processes that can be performed cyclically during LC.

Methods

The MS approach described here couples analyte sample nebulization by VSSI with corona discharge to achieve ionization via an atmospheric pressure chemical ionization (APCI)‐like process. A 28‐component small molecule standard mixture as well as a C. elegans metabolite extract are analyzed to determine potential for utilization in metabolomics experiments.

Results

For the standard panel, the cVSSI‐APCI approach is shown to better ionize half of all compounds compared to ESI. For the metabolomics extract, cVSSI‐APCI is shown to significantly outperform ESI for multiple compounds across a range of reversed‐phase LC solution conditions, while ESI is shown to outperform cVSSI‐APCI for other species. Manual cycling between field‐enabled cVSSI and cVSSI‐APCI ionization processes results in relatively rapid equilibration to distinct ionization processes with high reproducibility in compound ionization.

Conclusion

Cycling between ionization processes is accomplished on a timescale suitable with longer timescale LC runs. To obtain sufficient cycling rates for high‐throughput metabolomics experiments (~10 to 20 min) will require the use of high‐voltage, high‐power pulser electronics. The preliminary results suggest such an approach will be successful for online analyses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetabolomicsSpectrometry, Mass, Electrospray IonizationAnimalsAtmospheric PressureCaenorhabditis elegans

Stichwörter der Autor:innen

dual technique ionization sourcemass spectrometrymetabolomics

Autor:innen und Institutionen

  • Department of Chemistry, West Virginia University, Morgantown, West Virginia, USA.
  • Department of Chemistry, University of Louisville, Louisville, Kentucky, USA.
  • Department of Physics, West Virginia University, Morgantown, West Virginia, USA.
  • Invibragen, Inc., Morgantown, West Virginia, USA.
  • Department of Chemistry, Lehigh University, Bethlehem, Pennsylvania, USA.
  • Department of Biochemistry, Molecular Biology, & Biotechnology, University of Nevada Reno, Reno, Nevada, USA.

ORCID-Profile: Stephen J Valentine

Förderung

  • National Science Foundation

Zitieren

APA

Pursell, M., Ojanuga, A., Banerjee, C., Ezeigbo, E., Rahman, M., Dewasurendra, V. K., Hughart, T. B., Johnson, M. B., Sultana, M. N., Guo, X., Alexander, G., Patel, P., Li, P., Legleiter, J., & Valentine, S. J. (2026). Toward Metabolomics Analyses With Combined Capillary Vibrating Sharp‐Edge Spray Ionization and Atmospheric Pressure Chemical Ionization. Rapid Communications in Mass Spectrometry, 40(17). https://doi.org/10.1002/rcm.70110

Vancouver

Pursell M, Ojanuga A, Banerjee C, Ezeigbo E, Rahman M, Dewasurendra VK, et al. Toward Metabolomics Analyses With Combined Capillary Vibrating Sharp‐Edge Spray Ionization and Atmospheric Pressure Chemical Ionization. Rapid Communications in Mass Spectrometry. 2026;40(17). doi:10.1002/rcm.70110

BibTeX
@article{Pursell2026,
  author = {Pursell, Madison and Ojanuga, Adefolake and Banerjee, Chandrima and Ezeigbo, Ephraim and Rahman, Mohammad and Dewasurendra, Vikum K and Hughart, Thomas B and Johnson, Matthew B and Sultana, Mst Nigar and Guo, Xiaoting and Alexander, Gabriel and Patel, Priya and Li, Peng and Legleiter, Justin and Valentine, Stephen J},
  title = {Toward Metabolomics Analyses With Combined Capillary Vibrating Sharp‐Edge Spray Ionization and Atmospheric Pressure Chemical Ionization},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2026},
  volume = {40},
  number = {17},
  doi = {10.1002/rcm.70110}
}
Kostenlos starten →