EUVIMEDEUVIMED entdecken
Crossref

Microcolumn Liquid Chromatography—Atmospheric Pressure Chemical Ionisation Tandem Mass Spectrometric Determination of Nitrosamine Impurities From Pharmaceutical Products

Sanjay K Shendage, Maloth Rama Krishna iD, Maddala Nagaraju, Satya Sri Dharmika Kanakala, Jayvant Harlikar, Vijayasarathi V R Upadhyayula iD

Rapid Communications in Mass Spectrometry · 15.08.2026 · 40 (15)

DOI: 10.1002/rcm.70095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 01.05.2026. Verfasst von Sanjay K Shendage und 5 weiteren Autor:innen. Beteiligte Einrichtung: API-ADL, Cipla Ltd, Rasayani, Maharashtra, India. Hauptthemen laut MEDLINE: Nitrosamines, Drug Contamination, Tandem Mass Spectrometry. Die Arbeit nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Pharmaceutical analysis is vital for assessing drug quality and identifying impurities. The recent emergence of carcinogenic nitrosamine contaminants has escalated scrutiny, resulting in the withdrawal of multiple medications. This study focuses on developing robust analytical techniques to detect specific nitrosamine impurities in anticoagulant drugs (Apixaban, Rivaroxaban) and antidepressant drugs (Duloxetine HCl) while enhancing the eco‐friendliness of the method.

Methods

Nitrosamines were separated on a microbore liquid chromatographic column, and their concentrations were determined using a liquid chromatography system coupled to a triple quadrupole tandem mass spectrometer in positive/negative mode with atmospheric pressure chemical ionisation.

Results

The results showed good separation of analytes with sensitivities reaching the required standards. The method was validated as per ICH Q2(R2) guidelines. The linearity of the method was performed from 0.1 ng/g to 5 μg/g quantity of the nitrosamines. The obtained calibration curves showed excellent linearity with the square of regression coefficient ranging from 0.994 to 0.998. The determination accuracy ranged from 85.53% to 119.55%, with a relative standard deviation of 2.3% to 8.1%. The interday and intraday precisions were less than 10%. The findings illuminate intricate relative uncertainties ranging from 18.2% to 29.5% across three drug products. Regarding sustainability, the method scored 69 on the GAPI assessment and 0.67 on the AGREE assessment, indicating moderately green.

Conclusion

This validated method provides sensitivity and precision in detecting nitrosamine impurities in the selected pharmaceutical products in the limits specified by various pharmacopeias and compliant with ICH Q2 (R2) standards. The solvent consumption is relatively very low compared with that of the reported standard methods; hence, the method becomes environmentally friendly and economical.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NitrosaminesDrug ContaminationTandem Mass SpectrometryPharmaceutical PreparationsReproducibility of ResultsLimit of DetectionAtmospheric Pressure

Stichwörter der Autor:innen

LCMSenvironmental sustainabilitymethod validationnitrosaminespharmaceutical analysis

Substanzen

NitrosaminesPharmaceutical Preparations

Autor:innen und Institutionen

  • API-ADL, Cipla Ltd, Rasayani, Maharashtra, India.
  • Academy of Scientific and Innovative Research, Ghaziabad, India.
  • Centre for Mass Spectrometry, Department of Analytical & Structural Chemistry, CSIR-Indian Institute of Chemical Technology, Hyderabad, Telangana, India.

ORCID-Profile: Maloth Rama Krishna, Vijayasarathi V R Upadhyayula

Zitieren

APA

Shendage, S. K., Krishna, M. R., Nagaraju, M., Kanakala, S. S. D., Harlikar, J., & Upadhyayula, V. V. R. (2026). Microcolumn Liquid Chromatography—Atmospheric Pressure Chemical Ionisation Tandem Mass Spectrometric Determination of Nitrosamine Impurities From Pharmaceutical Products. Rapid Communications in Mass Spectrometry, 40(15). https://doi.org/10.1002/rcm.70095

Vancouver

Shendage SK, Krishna MR, Nagaraju M, Kanakala SSD, Harlikar J, Upadhyayula VVR. Microcolumn Liquid Chromatography—Atmospheric Pressure Chemical Ionisation Tandem Mass Spectrometric Determination of Nitrosamine Impurities From Pharmaceutical Products. Rapid Communications in Mass Spectrometry. 2026;40(15). doi:10.1002/rcm.70095

BibTeX
@article{Shendage2026,
  author = {Shendage, Sanjay K and Krishna, Maloth Rama and Nagaraju, Maddala and Kanakala, Satya Sri Dharmika and Harlikar, Jayvant and Upadhyayula, Vijayasarathi V R},
  title = {Microcolumn Liquid Chromatography—Atmospheric Pressure Chemical Ionisation Tandem Mass Spectrometric Determination of Nitrosamine Impurities From Pharmaceutical Products},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2026},
  volume = {40},
  number = {15},
  doi = {10.1002/rcm.70095}
}
Kostenlos starten →