EUVIMEDEUVIMED entdecken
Crossref

ESI–MS/MS Characterisation of Phenolic Reaction Products of Nitrogen Mustards and N , N ‐Dialkylaminoethyl‐2‐Chlorides and Their Rapid Screening by LC–MS/MS in Neutral Loss Scan Mode

M Nikita Singh, K G Harsha, V V S Lakshmi, T Jagadeshwar Reddy, S Prabhakar

Rapid Communications in Mass Spectrometry · 15.06.2026 · 40 (11)

DOI: 10.1002/rcm.70060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 10.03.2026. Verfasst von M Nikita Singh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Mass Spectrometry, Department of Analytical & Structural Chemistry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Nitrogen mustards (HN1, HN2 and HN3) and N , N ‐dialkylaminoethyl‐2‐chlorides (where alkyl = methyl, ethyl, isopropyl, or propyl) contain reactive chloride bonds that react with phenol in environmental samples to form phenolic reaction products. Identifying these products is crucial for the Chemical Weapons Convention (CWC) verification, as they serve as markers for the presence of scheduled chemicals.

Methods

Phenolic reaction products of nitrogen mustards ( 1 – 3 ) and N , N ‐dialkylaminoethyl‐2‐chlorides ( 4 – 13 ) were analysed using direct ESI–MS and LC–ESI–MS/MS on an Agilent Q‐TOF system. Product ion spectra for [M + H] + ions ( 1 – 13 ) were collected at varied collision energies. Isomers were separated via LC with an Agilent Eclipse AAA column and gradient elution. A targeted LC–MS/MS in neutral‐loss scan (94 u) method was developed and validated for rapid screening of compounds 1–13 in a complex aqueous sample.

Results

Distinct product ions observed in the MS/MS spectra of 1–13 enabled structural characterisation and differentiation between isomers. Major fragmentation involved loss of a phenol (94 u) and C–C bond cleavages, which were influenced by the structure and size of the alkyl groups. A neutral loss scan LC–MS/MS method was developed for rapid screening of 1 – 13 at low levels (LOD ~ 10 ppb; LOQ ~ 30 ppb), even within complex matrices.

Conclusions

Phenolic reaction products of nitrogen mustards and N , N ‐dialkylaminoethyl‐2‐chlorides were comprehensively characterised, including isomer differentiation, through their ESI–MS/MS product ion spectra. The validated LC–MS/MS neutral‐loss scan method enabled efficient screening of these markers in complex samples. These LC–MS/MS methods are highly valuable for OPCW proficiency testing and CWC verification programs.

Schlagwörter

Stichwörter der Autor:innen

LC–ESI–MS/MSOPCW proficiency testingchemical warfare agentschemical weapons conventionneutral loss scan modenitrogen mustardsphenolic reaction products

Autor:innen und Institutionen

  • Centre for Mass Spectrometry, Department of Analytical & Structural Chemistry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India.
  • Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India.

Zitieren

APA

Singh, M. N., Harsha, K. G., Lakshmi, V. V. S., Reddy, T. J., & Prabhakar, S. (2026). ESI–MS/MS Characterisation of Phenolic Reaction Products of Nitrogen Mustards and N , N ‐Dialkylaminoethyl‐2‐Chlorides and Their Rapid Screening by LC–MS/MS in Neutral Loss Scan Mode. Rapid Communications in Mass Spectrometry, 40(11). https://doi.org/10.1002/rcm.70060

Vancouver

Singh MN, Harsha KG, Lakshmi VVS, Reddy TJ, Prabhakar S. ESI–MS/MS Characterisation of Phenolic Reaction Products of Nitrogen Mustards and N , N ‐Dialkylaminoethyl‐2‐Chlorides and Their Rapid Screening by LC–MS/MS in Neutral Loss Scan Mode. Rapid Communications in Mass Spectrometry. 2026;40(11). doi:10.1002/rcm.70060

BibTeX
@article{Singh2026,
  author = {Singh, M Nikita and Harsha, K G and Lakshmi, V V S and Reddy, T Jagadeshwar and Prabhakar, S},
  title = {ESI–MS/MS Characterisation of Phenolic Reaction Products of Nitrogen Mustards and N , N ‐Dialkylaminoethyl‐2‐Chlorides and Their Rapid Screening by LC–MS/MS in Neutral Loss Scan Mode},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2026},
  volume = {40},
  number = {11},
  doi = {10.1002/rcm.70060}
}
Kostenlos starten →