EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Novel Peak‐Shape Aware Approach for Mass Alignment in Mass Spectrometry

Thomas Vanhemel iD, Melanie Nijs iD, Angeliki Birmpili iD, Tim F E Hendriks iD, Eva Cuypers iD, Bart De Moor iD

Rapid Communications in Mass Spectrometry · 28.02.2026 · 40 (4)

DOI: 10.1002/rcm.10172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 30.11.2025. Verfasst von Thomas Vanhemel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering (ESAT), STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, KU Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Algorithms, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Mass Spectrometry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: KU Leuven, European Research Council, Industrial Research Fund, Leuven Research and Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

In mass spectrometry measurements, mass shifts may be inadvertently introduced due to instrumental drift and calibration inaccuracies, potentially compromising the accuracy of subsequent data analysis. This work presents a novel, label‐free algorithm to improve relative mass alignment between mass spectra. The warping function is modeled as a natural cubic spline, a suitable model for gradual, nonlinear mass shifts.

Methods

The algorithm is validated on a dataset generated from human glioblastoma multiforme samples using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry imaging (MALDI‐TOF MSI) and rapid evaporative ionization mass spectrometry (REIMS), and public datasets generated from MALDI‐TOF and desorption electrospray ionization (DESI) Orbitrap instruments.

Results

The algorithm considerably reduces the mass dispersion of the dataset and improves the similarity to a reference mass spectrum for MALDI‐TOF, REIMS and DESI‐Orbitrap data. It is demonstrated that the proposed method reliably corrects for severe mass shifts. The algorithm is competitive in speed and mass dispersion reduction compared to MSIWarp, a common method to correct for mass misalignment.

Conclusions

This paper presents a novel algorithm to reduce relative mass misalignment for mass spectrometry, validated on an extensive dataset. Thanks to the use of profile data, the peak shapes contribute to the computation of the warping function, and the warping function is approximated in a robust manner. An open‐source Python implementation of the proposed methodology will be made accessible on GitHub: https://github.com/VanhemelThomas/psalign .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationMass SpectrometryHumansGlioblastomaSpectrometry, Mass, Electrospray Ionization

Stichwörter der Autor:innen

label‐free mass alignmentmass shiftmass spectrometrymass spectrometry imaging

Autor:innen und Institutionen

  • Department of Electrical Engineering (ESAT), STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, KU Leuven, Leuven, Belgium.
  • Department of Communication Sciences, University of Antwerp, Antwerp, Belgium.
  • The Maastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry (IMS), Maastricht University, Maastricht, the Netherlands.
  • Fellow IEEE, SIAM, IFAC.

ORCID-Profile: Thomas Vanhemel, Melanie Nijs, Angeliki Birmpili, Tim F E Hendriks, Eva Cuypers, Bart De Moor

Förderung

  • KU Leuven
  • European Research Council
  • Industrial Research Fund, Leuven Research and Development
  • Fonds Wetenschappelijk Onderzoek
  • EWI: the Flanders AI Research Program
  • Agentschap Innoveren en Ondernemen
  • FOD Volksgezondheid, Veiligheid van de Voedselketen en Leefmilieu
  • Interreg Vlaanderen-Nederland (Molecular Brain Tumor Detector Project)

Zitieren

APA

Vanhemel, T., Nijs, M., Birmpili, A., Hendriks, T. F. E., Cuypers, E., & De Moor, B. (2026). A Novel Peak‐Shape Aware Approach for Mass Alignment in Mass Spectrometry. Rapid Communications in Mass Spectrometry, 40(4). https://doi.org/10.1002/rcm.10172

Vancouver

Vanhemel T, Nijs M, Birmpili A, Hendriks TFE, Cuypers E, De Moor B. A Novel Peak‐Shape Aware Approach for Mass Alignment in Mass Spectrometry. Rapid Communications in Mass Spectrometry. 2026;40(4). doi:10.1002/rcm.10172

BibTeX
@article{Vanhemel2026,
  author = {Vanhemel, Thomas and Nijs, Melanie and Birmpili, Angeliki and Hendriks, Tim F E and Cuypers, Eva and De Moor, Bart},
  title = {A Novel Peak‐Shape Aware Approach for Mass Alignment in Mass Spectrometry},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2026},
  volume = {40},
  number = {4},
  doi = {10.1002/rcm.10172}
}
Kostenlos starten →