Isotopologue Ratios Identify 13 C‐Depleted Biomarkers in Environmental Samples Impacted by Methane Turnover
Rapid Communications in Mass Spectrometry · 2025
DOI: 10.1002/rcm.10118 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2025. Verfasst von Janina Groninga und 3 weiteren Autor:innen. Beteiligte Einrichtung: MARUM - Center for Marine Environmental Sciences, and Faculty of Geosciences, University of Bremen, Bremen, Germany. Hauptthemen laut MEDLINE: Methane, Carbon Isotopes, Geologic Sediments, Lipids. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 94 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Rationale
The stable carbon isotopic composition (δ 13 C) of individual lipids is of great value in studying carbon cycling. Among those, microbial lipids in sediments impacted by high methane turnover stand out due to their uniquely depleted isotopic fingerprint. However, gas chromatography/isotope ratio mass spectrometry (GC/irMS) is limited to volatile compounds, whereas intact polar lipids require extensive preprocessing, which results in the loss of chemotaxonomic information. Expanding compound‐specific isotopic information to intact polar lipids would enhance insights into the microbial turnover of methane.
Methods
We performed ultra‐high‐performance liquid chromatography/electrospray ionization/high‐resolution mass spectrometry (UHPLC/ESI/HRMS) to analyze standards of archaeol and lipid extracts from a diverse set of sediment samples of a hydrothermal methane seep system. Using the ratio of the M1 isotopologue over the monoisotopic isotopologue M0, we calculated the δ 13 C values of archaeol and various polar, non‐GC‐amenable lipids. The δ 13 C values of archaeol obtained via ratios were compared to those measured via GC/irMS. Results δ 13 C values of archaeol determined in natural samples via GC/irMS and the UHPLC/HRMS approach were strongly correlated ( R 2 = 0.94; N = 76–82) across a wide range of δ 13 C values (GC‐irMS = −119‰ to −34‰). Biomarkers associated with methane turnover consistently yielded δ 13 C values below −60‰, whereas the δ 13 C values of compounds presumably associated with the photosynthesis‐based food web remained above −45‰. UHPLC/HRMS measurements of archaeol standard further indicated that δ 13 C values can be reliably determined across an M0 signal‐intensity range of approximately one order of magnitude.
Conclusions
Our results highlight that the M1/M0 ratio from UHPLC/HRMS measurements can be utilized to evaluate the carbon isotopic fingerprint of non‐GC‐amenable lipids and to reliably detect lipid biomarkers putatively associated with microbial methane turnover carrying extremely depleted isotopic signatures. This paves the way for a comprehensive exploration of intact lipids associated with microbial methane turnover in environmental samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- MARUM - Center for Marine Environmental Sciences, and Faculty of Geosciences, University of Bremen, Bremen, Germany.
- Department of Earth Sciences, University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: Janina Groninga, Min Song
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Groninga, J., Lipp, J., Song, M., & Hinrichs, K. U. (2025). Isotopologue Ratios Identify 13 C‐Depleted Biomarkers in Environmental Samples Impacted by Methane Turnover. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.10118
Vancouver
Groninga J, Lipp J, Song M, Hinrichs KU. Isotopologue Ratios Identify 13 C‐Depleted Biomarkers in Environmental Samples Impacted by Methane Turnover. Rapid Communications in Mass Spectrometry. 2025. doi:10.1002/rcm.10118
BibTeX
@article{Groninga2025,
author = {Groninga, Janina and Lipp, Julius and Song, Min and Hinrichs, Kai-Uwe},
title = {Isotopologue Ratios Identify 13 C‐Depleted Biomarkers in Environmental Samples Impacted by Methane Turnover},
journal = {Rapid Communications in Mass Spectrometry},
year = {2025},
doi = {10.1002/rcm.10118}
}
EUVIMED