EUVIMEDEUVIMED entdecken
Crossref

Parameter‐Optimized Fabrication of Submicron Nanoelectrospray Emitters for Enhanced Native Mass Spectrometry

Ting Zhu, Sujun Yan, Xinhai Zhu, Zilong Chen iD

Rapid Communications in Mass Spectrometry · 2025

DOI: 10.1002/rcm.10080 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2025. Verfasst von Ting Zhu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Sun Yat-Sen University, Guangzhou, China. Hauptthemen laut MEDLINE: Nanotechnology, Spectrometry, Mass, Electrospray Ionization. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Submicron nanoelectrospray emitters, which suppress nonspecific aggregation and accommodate high‐salt buffers, have significantly enhanced native mass spectrometry (native MS) performance. Current technical challenges in fabricating such precision emitters, coupled with commercial products' high costs and limited size specifications, hinder diversified analytical demands. Developing cost‐effective and customizable fabrication strategies is therefore imperative to overcome technical barriers, improve instrumental performance, and broaden application scopes.

Methods

The effects of key pulling parameters, such as heating power (HEAT), pulling force (PULL), heating width (FILAMENT), cooling delay (DELAY), and trigger speed (VELOCITY), on emitter morphology were systematically studied using a laser puller. Self‐fabricated emitters were evaluated by analyzing three proteins (BSA, cytochrome C, IgG) under near‐physiological conditions via nMS.

Results

HEAT and PULL were identified as key factors controlling the tip IDs and cone lengths. By employing multiple‐loop processing to reduce the pulling force, we successfully fabricated emitters suitable for nMS. This process reduced the tip ID from 3 to 800 nm, enhancing salt tolerance for BSA from 300 to 800 μM, cytochrome C from 800 to 2000 μM, and IgG from 10 to 50 μM. Meanwhile, detection sensitivity can be greatly improved for BSA detection limits dropped from 0.1 to 0.06 μM, cytochrome C from 1.5 to 0.25 nM, and IgG from 0.7 to 0.1 μM. Additionally, nonspecific protein aggregation was reduced.

Conclusion

We identified HEAT and PULL as the critical parameters for optimizing emitter inner diameter (ID) and cone length, while VELOCITY‐PULL interactions specifically enhanced tip flatness. Multi‐loop operations significantly optimize emitter tip morphology. This enabled controlled fabrication of emitters spanning submicron‐scale (200 nm) to micron‐scale (8 μm) IDs, with submicron‐range parameter optimization. This provides a practical reference for users requiring emitters of varying specifications, thereby advancing the development of nMS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NanotechnologySpectrometry, Mass, Electrospray IonizationCytochromes cSerum Albumin, BovineImmunoglobulin GAnimalsCattleProteinsEquipment DesignLimit of Detection

Stichwörter der Autor:innen

native mass spectrometryprocess parameterssubmicron nanoelectrospray emitters

Substanzen

Cytochromes cSerum Albumin, BovineImmunoglobulin GProteins

Autor:innen und Institutionen

  • School of Chemistry, Sun Yat-Sen University, Guangzhou, China.
  • Instrumental Analysis & Research Center, Sun Yat-Sen University, Guangzhou, China.

ORCID-Profile: Zilong Chen

Zitieren

APA

Zhu, T., Yan, S., Zhu, X., & Chen, Z. (2025). Parameter‐Optimized Fabrication of Submicron Nanoelectrospray Emitters for Enhanced Native Mass Spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.10080

Vancouver

Zhu T, Yan S, Zhu X, Chen Z. Parameter‐Optimized Fabrication of Submicron Nanoelectrospray Emitters for Enhanced Native Mass Spectrometry. Rapid Communications in Mass Spectrometry. 2025. doi:10.1002/rcm.10080

BibTeX
@article{Zhu2025,
  author = {Zhu, Ting and Yan, Sujun and Zhu, Xinhai and Chen, Zilong},
  title = {Parameter‐Optimized Fabrication of Submicron Nanoelectrospray Emitters for Enhanced Native Mass Spectrometry},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2025},
  doi = {10.1002/rcm.10080}
}
Kostenlos starten →