Precision Chemotherapy: Optimizing Calibration for Rapid Determination of Blood Methotrexate by Tandem Mass Spectrometry ± Liquid Chromatography
Rapid Communications in Mass Spectrometry · 2025
DOI: 10.1002/rcm.10053 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2025. Verfasst von Dennis J Dietzen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, Phoenix Children's Hospital, Phoenix, Arizona, USA. Hauptthemen laut MEDLINE: Methotrexate, Tandem Mass Spectrometry, Antimetabolites, Antineoplastic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Themen: Onkologische Pflege
Abstract (Originalsprache)
Background
Rapid therapeutic monitoring of high‐dose methotrexate (MTX) chemotherapy is essential to avoid toxicity. MTX concentrations are commonly monitored using immunoassays that are limited by narrow dynamic range and metabolite cross reactivity. Mass spectrometry may improve the molecular specificity of MTX analysis but is limited by slow throughput and extensive calibration. In this study, we examined the consequences of eliminating LC from MS/MS and foregoing external calibration to enable rapid determination of MTX.
Methods
MTX (m/z 455 → 308), was assessed using UPLC–MS/MS or flow‐injection MS/MS using a six‐point external calibration scheme with a single deuterated internal standard, 4‐point internal calibration using 13 C 5 , 13 C 6 , 13 C 11 , and 13 C 14 ‐MTX, or by single point calibration with the single deuterated internal standard. Accuracy, precision, and resistance to hemolysis, icterus, and lipemia were compared with immunoassay.
Results
Across all six injection/calibration schemes, imprecision ranged from 2.5% to 10% (CV) from 0.05–10 μM. Regardless of calibration scheme, MS/MS ± LC was more resistant to interference from hemolysis and bilirubin than immunoassay. MS/MS ± LC determination of MTX was compared with immunoassay in 81–100 plasma specimens with MTX concentrations ranging from 0.05–81 μM. Intercept estimates all included zero with 95% confidence. Estimates of slopes versus immunoassay for each of the six analytic approaches ranged from 0.88 to 1.09.
Conclusions
Eliminating LC and external calibration enabled rapid, precise, and accurate determination of MTX concentrations in plasma. Minimalist but robust approaches such as these may enable the use of MS for routine MTX determination in time‐sensitive clinical circumstances.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology and Laboratory Medicine, Phoenix Children's Hospital, Phoenix, Arizona, USA.
- Creighton University, Phoenix, Arizona, USA.
ORCID-Profile: Dennis J Dietzen
Zitieren
APA
Dietzen, D. J., & Blair, C. J. (2025). Precision Chemotherapy: Optimizing Calibration for Rapid Determination of Blood Methotrexate by Tandem Mass Spectrometry ± Liquid Chromatography. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.10053
Vancouver
Dietzen DJ, Blair CJ. Precision Chemotherapy: Optimizing Calibration for Rapid Determination of Blood Methotrexate by Tandem Mass Spectrometry ± Liquid Chromatography. Rapid Communications in Mass Spectrometry. 2025. doi:10.1002/rcm.10053
BibTeX
@article{Dietzen2025,
author = {Dietzen, Dennis J and Blair, Connor J},
title = {Precision Chemotherapy: Optimizing Calibration for Rapid Determination of Blood Methotrexate by Tandem Mass Spectrometry ± Liquid Chromatography},
journal = {Rapid Communications in Mass Spectrometry},
year = {2025},
doi = {10.1002/rcm.10053}
}
EUVIMED