Does reducing Stevenson screen volume bias air temperature measurements? A theoretical determination

Alberto Boretti

Quarterly Journal of the Royal Meteorological Society · 23.11.2026

DOI: 10.1002/qj.70363 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quarterly Journal of the Royal Meteorological Society, online erschienen am 23.11.2026. Verfasst von Alberto Boretti. Die Arbeit nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Empirical studies investigating whether smaller Stevenson screens bias air temperature readings show contradictory results: some report a positive warming bias of 0.5–0.9°C when switching from large to small screens, while others find no significant bias. This work argues that the question may not be resolved by further observation alone, given variations in site conditions, maintenance, and experimental design. Instead, we derive a possible resolution from first‐principles heat transfer analysis, treating the Stevenson screen as a passively ventilated radiation shield in thermal equilibrium. Starting from the steady‐state energy balance – absorbed radiative flux equals convective plus radiative heat loss – the temperature bias (screen interior minus ambient air) is expressed as a function of screen volume. A dimensionless formulation introduces the bias as a function of the Biot number and a modified radiation number. The derivation shows that convective cooling scales as a power law of the product of screen volume raised to an exponent and external wind speed. The Nusselt number follows a standard correlation with Reynolds and Prandtl numbers, with characteristic length scale proportional to the cube root of screen volume. Substituting into the linearised energy balance yields a theoretical model predicting that for any non‐zero absorbed radiation, the bias is strictly positive and increases monotonically as screen volume decreases. The model also resolves contradictory empirical findings: the bias is not a fixed constant but a strong function of environmental conditions (solar radiation, wind speed, humidity, sky temperature). Thus, while empiricism remains divided, theory provides a physically grounded prediction: reducing Stevenson screen volume introduces a systematic upward bias under most daytime conditions with non‐zero absorbed radiation and moderate‐to‐low ventilation; the magnitude remains uncertain without experimental calibration of the scaling exponents and depends on the radiative and ventilatory conditions.

Zitieren

APA

Boretti, A. (2026). Does reducing Stevenson screen volume bias air temperature measurements? A theoretical determination. Quarterly Journal of the Royal Meteorological Society. https://doi.org/10.1002/qj.70363

Vancouver

Boretti A. Does reducing Stevenson screen volume bias air temperature measurements? A theoretical determination. Quarterly Journal of the Royal Meteorological Society. 2026. doi:10.1002/qj.70363

BibTeX
@article{Boretti2026,
  author = {Boretti, Alberto},
  title = {Does reducing Stevenson screen volume bias air temperature measurements? A theoretical determination},