Determining precipitable water vapour from upper‐air temperature, pressure and geopotential height

António P. Ferreira, Luis Gimeno

Quarterly Journal of the Royal Meteorological Society · 2024-01 · 150 (758) · 484-522

DOI: 10.1002/qj.4609 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quarterly Journal of the Royal Meteorological Society, online erschienen am 02.01.2024. Verfasst von António P. Ferreira und 1 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 104 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Radiosonde measurements of relative humidity (RH) are the main source of uncertainty in precipitable water vapour (PWV) calculation from pressure, temperature, and RH/dewpoint (PTU) data. This paper presents a formula expressing PWV in terms of pressure and temperature as functions of geopotential height (GPH), thereby allowing the PWV to be determined: (1) without any moisture‐related calculations other than those involved in measuring GPH (in radiosondes with a pressor sensor) or pressure (otherwise); (2) without relying on humidity measurements by using Global Positioning System (GPS)‐based GPH according to the gravity field, provided that pressure is directly measured. The numerical instability associated with random data errors or deviations from hydrostatic equilibrium makes the second approach unfeasible on short time scales, revealing discrepancies between the PTU‐ and GPS‐based GPHs; however, the estimation of long‐term average PWV above a location is not hindered. The estimation of PWV without humidity data was tested using high‐resolution data from 62 upper‐air stations operated by the NOAA National Weather Service. The seasonal mean {DJF, MAM, JJA, SON} PWV from the surface to 300 hPa calculated from PT and GPS data over the period 2016–2018, after rejecting individual estimates inconsistent with the 0%–100% RH range, showed a mean bias error of {−0.1, +0.1, −1.4, −0.9} kg·m −2 relative to the PTU‐based values across the stations, and a RMSE ranging from 2.4 (DJF) to 3.2 (JJA) kg·m −2 . By restricting the analysis to observations with above‐average matching between the PTU‐ and GPS‐based GPH, the bias magnitude and RMSE reduced respectively to less than 0.5 and 1 kg·m −2 in all seasons. The results indicate that evaluating the long‐term agreement between the two PWV calculation methods at different sites could be useful in detecting systematic observation errors in GPS radiosonde systems using a pressure sensor.

Zitieren

APA

Ferreira, A. P., & Gimeno, L. (2024). Determining precipitable water vapour from upper‐air temperature, pressure and geopotential height. Quarterly Journal of the Royal Meteorological Society, 150(758), 484-522. https://doi.org/10.1002/qj.4609

Vancouver

Ferreira AP, Gimeno L. Determining precipitable water vapour from upper‐air temperature, pressure and geopotential height. Quarterly Journal of the Royal Meteorological Society. 2024;150(758):484-522. doi:10.1002/qj.4609

BibTeX
@article{Ferreira2024,
  author = {Ferreira, António P. and Gimeno, Luis},
  title = {Determining precipitable water vapour from upper‐air temperature, pressure and geopotential height},
  journal = {Quarterly Journal of the Royal Meteorological Society},
  year = {2024},
  volume = {150},
  number = {758},
  pages = {484--522},
  doi = {10.1002/qj.4609}
}