EUVIMEDEUVIMED entdecken
Crossref

Pulsed X‐Ray Detector Based on Vertical p‐NiO/ β ‐Ga 2 O 3 Heterojunction Diode

Silong Zhang, Yuxin Deng, Liang Chen, Shiyi He, Xue Du, Fangbao Wang, Yuru Lai, Silei Zhong, Naizhe Zhao, Yang Li, Leidang Zhou, Xing Lu und 1 weitere

physica status solidi (b) · 2025-08 · 262 (8)

DOI: 10.1002/pssb.202400363 ↗

Kurz gefasst

Fachartikel in der Zeitschrift physica status solidi (b), online erschienen am 20.09.2024. Verfasst von Silong Zhang und 12 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gallium Oxide (Ga 2 O 3 ) devices have shown great potential for radiation detection. However, developing Ga 2 O 3 detectors for pulsed radiation monitoring is still challenging, which requires high response sensitivity ( R ), low noise, high time resolution, and linear outputs. Herein, a vertical p‐NiO/ β‐ Ga 2 O 3 heterojunction diode (HJD) is fabricated and its performance in X‐ray detection is analyzed. Benefiting from the high quality of the p‐n heterojunction, the HJD exhibits a low‐leakage current density of less than 1.73 × 10 −7 A cm −2 at 100 V and features a high R of 7.92 μC Gy −1 cm −2 , a low noise equivalent dose rate of 9.14 × 10 −12 Gy −1 Hz −0.5 at an X‐ray dose rate of 0.383 Gy s −1 , and good linear outputs to X‐ray dose rates from 0.0383 to 1.149 Gy s −1 . The conductive process of the HJD detector is dominated by the tunneling mechanism, which leads to a longer response time associated with the trapping and releasing process of the deep‐level traps under the continuous X‐ray illumination. However, the pulsed X‐ray response property shows no significant influence from the slow trapping/releasing process of the traps. As a result, pulsed X‐ray radiation detection with a 50 ns full width is achieved, and the time resolution of the detector is characterized to be 3.31 ns by a 20 ps laser source.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, S., Deng, Y., Chen, L., He, S., Du, X., Wang, F., Lai, Y., Zhong, S., Zhao, N., Li, Y., Zhou, L., Lu, X., & Ouyang, X. (2025). Pulsed X‐Ray Detector Based on Vertical p‐NiO/ β ‐Ga 2 O 3 Heterojunction Diode. physica status solidi (b), 262(8). https://doi.org/10.1002/pssb.202400363

Vancouver

Zhang S, Deng Y, Chen L, He S, Du X, Wang F, et al. Pulsed X‐Ray Detector Based on Vertical p‐NiO/ β ‐Ga 2 O 3 Heterojunction Diode. physica status solidi (b). 2025;262(8). doi:10.1002/pssb.202400363

BibTeX
@article{Zhang2025,
  author = {Zhang, Silong and Deng, Yuxin and Chen, Liang and He, Shiyi and Du, Xue and Wang, Fangbao and Lai, Yuru and Zhong, Silei and Zhao, Naizhe and Li, Yang and Zhou, Leidang and Lu, Xing and Ouyang, Xiaoping},
  title = {Pulsed X‐Ray Detector Based on Vertical p‐NiO/ β ‐Ga 2 O 3 Heterojunction Diode},
  journal = {physica status solidi (b)},
  year = {2025},
  volume = {262},
  number = {8},
  doi = {10.1002/pssb.202400363}
}
Kostenlos starten →