EUVIMEDEUVIMED entdecken
Crossref

Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings

Xue Li iD, David Nuyttens, Tao Xu, Zeng Jin, Shilin Wang iD, Xiaonlan Lv

Pest Management Science · 2024

DOI: 10.1002/ps.8333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pest Management Science, 2024. Verfasst von Xue Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Agricultural Facilities and Equipment, Jiangsu Academy of Agricultural Sciences, Nanjing, China. Hauptthemen laut MEDLINE: Hydrodynamics, Computer Simulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND High‐efficient pesticide application equipment for protected cultivation is scarce. In response, a fixed‐pipe twin‐fluid clod fogger (FTCF) was proposed as a potential solution. To investigate the optimal nozzle layout and spray performance, a computational fluid dynamics (CFD) model was used to study the airflow distribution and spray deposition of a FTCF with different nozzle settings using the Euler–Lagrange approach. Specifically, two piping configurations, middle‐cross‐inverted (MCI) and bilateral‐malposed‐opposite (BMO), were combined with three nozzle spacings (2 m, 3 m, 4 m) resulting in six nozzle settings. Additionally, a greenhouse spray trial was conducted to test the performance of FTCF with the selected nozzle settings and to validate the model. RESULTS The simulation results revealed that MCI piping configuration exhibited a stronger airflow disturbance compared to BMO configuration, indicating a more significant air‐guided effect in the MCI configuration. Combining this finding with the ground droplet distribution analysis of MCI piping configuration, it was observed that MCI‐2 m had the lowest coefficient of variation (CV) for ground deposition (20.56%). Consequently, MCI‐2 m was determined as the most optimal nozzle setting. Verification results demonstrated a high consistency between experimental and simulated spray deposition results. CONCLUSIONS The FTCF system effectively generated a three‐dimensional airflow field throughout the greenhouse environment. Furthermore, jet flow produced by FTCF disrupted the overall airflow pattern within the greenhouse space which facilitated droplet suspension and dispersion. This study provides valuable insights and innovative ideas for enhancing pesticide application technologies in protected cultivations. © 2024 Society of Chemical Industry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrodynamicsComputer SimulationPesticidesAgricultureModels, Theoretical

Stichwörter der Autor:innen

Euler–Lagrange approachairflow distributiongreenhouse sprayspray depositiontwin‐fluid nozzle

Substanzen

Pesticides

Autor:innen und Institutionen

  • Institute of Agricultural Facilities and Equipment, Jiangsu Academy of Agricultural Sciences, Nanjing, China.
  • Key Laboratory of Horticultural Equipment, Ministry of Agriculture and Rural Affairs, Nanjing, China.
  • Flanders Research Institute for Agriculture, Fisheries and Food (ILVO), Merelbeke, Belgium.
  • College of Engineering, Nanjing Agriculture University, Nanjing, China.

ORCID-Profile: Xue Li, Shilin Wang

Zitieren

APA

Li, X., Nuyttens, D., Xu, T., Jin, Z., Wang, S., & Lv, X. (2024). Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings. Pest Management Science. https://doi.org/10.1002/ps.8333

Vancouver

Li X, Nuyttens D, Xu T, Jin Z, Wang S, Lv X. Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings. Pest Management Science. 2024. doi:10.1002/ps.8333

BibTeX
@article{Li2024,
  author = {Li, Xue and Nuyttens, David and Xu, Tao and Jin, Zeng and Wang, Shilin and Lv, Xiaonlan},
  title = {Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings},
  journal = {Pest Management Science},
  year = {2024},
  doi = {10.1002/ps.8333}
}
Kostenlos starten →