Fachartikel in der Zeitschrift Pest Management Science, 2024. Verfasst von Xue Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Agricultural Facilities and Equipment, Jiangsu Academy of Agricultural Sciences, Nanjing, China. Hauptthemen laut MEDLINE: Hydrodynamics, Computer Simulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND High‐efficient pesticide application equipment for protected cultivation is scarce. In response, a fixed‐pipe twin‐fluid clod fogger (FTCF) was proposed as a potential solution. To investigate the optimal nozzle layout and spray performance, a computational fluid dynamics (CFD) model was used to study the airflow distribution and spray deposition of a FTCF with different nozzle settings using the Euler–Lagrange approach. Specifically, two piping configurations, middle‐cross‐inverted (MCI) and bilateral‐malposed‐opposite (BMO), were combined with three nozzle spacings (2 m, 3 m, 4 m) resulting in six nozzle settings. Additionally, a greenhouse spray trial was conducted to test the performance of FTCF with the selected nozzle settings and to validate the model. RESULTS The simulation results revealed that MCI piping configuration exhibited a stronger airflow disturbance compared to BMO configuration, indicating a more significant air‐guided effect in the MCI configuration. Combining this finding with the ground droplet distribution analysis of MCI piping configuration, it was observed that MCI‐2 m had the lowest coefficient of variation (CV) for ground deposition (20.56%). Consequently, MCI‐2 m was determined as the most optimal nozzle setting. Verification results demonstrated a high consistency between experimental and simulated spray deposition results. CONCLUSIONS The FTCF system effectively generated a three‐dimensional airflow field throughout the greenhouse environment. Furthermore, jet flow produced by FTCF disrupted the overall airflow pattern within the greenhouse space which facilitated droplet suspension and dispersion. This study provides valuable insights and innovative ideas for enhancing pesticide application technologies in protected cultivations. © 2024 Society of Chemical Industry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Agricultural Facilities and Equipment, Jiangsu Academy of Agricultural Sciences, Nanjing, China.
- Key Laboratory of Horticultural Equipment, Ministry of Agriculture and Rural Affairs, Nanjing, China.
- Flanders Research Institute for Agriculture, Fisheries and Food (ILVO), Merelbeke, Belgium.
- College of Engineering, Nanjing Agriculture University, Nanjing, China.
ORCID-Profile: Xue Li, Shilin Wang
Zitieren
APA
Li, X., Nuyttens, D., Xu, T., Jin, Z., Wang, S., & Lv, X. (2024). Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings. Pest Management Science. https://doi.org/10.1002/ps.8333
Vancouver
Li X, Nuyttens D, Xu T, Jin Z, Wang S, Lv X. Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings. Pest Management Science. 2024. doi:10.1002/ps.8333
BibTeX
@article{Li2024,
author = {Li, Xue and Nuyttens, David and Xu, Tao and Jin, Zeng and Wang, Shilin and Lv, Xiaonlan},
title = {Spray performance simulation and experiment analysis of a greenhouse fixed‐pipe twin‐fluid cold fogger with different nozzle settings},
journal = {Pest Management Science},
year = {2024},
doi = {10.1002/ps.8333}
}
EUVIMED