EUVIMEDEUVIMED entdecken
Evaluationsstudie

Establishment and evaluation of two MIRA rapid detection methods for tomato chlorosis virus ( ToCV )

JunXia Shi iD, JiaJia Wang, WenQi Xie, LuXi Liu, XiaoBin Zheng, ChunPing Yang iD, HuaBao Chen, ZhaoHuan Lu, Cheng Yang, BaoLin Shao

Pest Management Science · 2026

DOI: 10.1002/ps.70589 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Pest Management Science, 2026. Verfasst von JunXia Shi und 9 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Rice Seed Quarantine and Germplasm Identification and Testing, Chengdu, China. Hauptthemen laut MEDLINE: Crinivirus, Nucleic Acid Amplification Techniques, Solanum lycopersicum, Plant Diseases. Die Arbeit nennt 55 Literaturangaben. Gefördert von: Natural Science Foundation Project of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Tomato chlorosis virus (ToCV) represents a major threat to the tomato industry in China. Conventional Reverse Transcription quantitative Polymerase Chain Reaction (RT–qPCR) assays require expensive thermal cyclers and are poorly suited to on‐site screening in fields or at ports of entry. Here, two multi‐enzyme isothermal rapid amplification (MIRA) systems targeting the highly conserved minor capsid protein (CPm) region of ToCV were developed: (i) a basic MIRA–electrophoresis assay (B‐MIRA), and (ii) a fluorescent MIRA–real‐time assay (F‐MIRA). Primers/probes, reaction temperature, sensitivity and specificity were systematically optimized, and performance was validated with field samples. RESULTS The basic assay completed amplification at 41 °C within 30 min, generating a single 250 bp band; the limit of detection (LOD) was 2.78 × 10 −1 pg/μL. The fluorescent assay reached its endpoint in 20 min at 37 °C using the optimal primer/probe set F2/R1 + P (Ct = 12.4 ± 0.3 min); LOD was 2.78 × 10 −1 pg/μL. CONCLUSION The B‐MIRA and F‐MIRA assays developed in this study can reliably detect ToCV within 20 min with high sensitivity. Free of bulky instrumentation or professional laboratories, the protocols can be directly applied to seedling quarantine, field‐side early inspection and border control, offering an accurate and ready‐to‐use diagnostic tool for the green management of ToCV. © 2026 Society of Chemical Industry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrinivirusNucleic Acid Amplification TechniquesSolanum lycopersicumPlant DiseasesSensitivity and SpecificityRapid Diagnostic TestsLimit of Detection

Stichwörter der Autor:innen

CPmMIRAport quarantinerapid detectiontomato chlorosis virus

Autor:innen und Institutionen

  • National Key Laboratory of Rice Seed Quarantine and Germplasm Identification and Testing, Chengdu, China.
  • College of Agronomy, Sichuan Agricultural University, Chengdu, China.
  • Dazhou Key Laboratory of Agricultural Resources Development and Ecological Conservation in Daba Mountain, Sichuan University of Arts and Science, Dazhou, PR China.

ORCID-Profile: JunXia Shi, ChunPing Yang

Förderung

  • Natural Science Foundation Project of Sichuan Province

Zitieren

APA

Shi, J., Wang, J., Xie, W., Liu, L., Zheng, X., Yang, C., Chen, H., Lu, Z., Yang, C., & Shao, B. (2026). Establishment and evaluation of two MIRA rapid detection methods for tomato chlorosis virus ( ToCV ). Pest Management Science. https://doi.org/10.1002/ps.70589

Vancouver

Shi J, Wang J, Xie W, Liu L, Zheng X, Yang C, et al. Establishment and evaluation of two MIRA rapid detection methods for tomato chlorosis virus ( ToCV ). Pest Management Science. 2026. doi:10.1002/ps.70589

BibTeX
@article{Shi2026,
  author = {Shi, JunXia and Wang, JiaJia and Xie, WenQi and Liu, LuXi and Zheng, XiaoBin and Yang, ChunPing and Chen, HuaBao and Lu, ZhaoHuan and Yang, Cheng and Shao, BaoLin},
  title = {Establishment and evaluation of two MIRA rapid detection methods for tomato chlorosis virus ( ToCV )},
  journal = {Pest Management Science},
  year = {2026},
  doi = {10.1002/ps.70589}
}
Kostenlos starten →