EUVIMEDEUVIMED entdecken
Crossref

A spectrophotometric trimethylamine monooxygenase assay

Shiwangi Maurya, Abhishek Singh, Gurunath Ramanathan iD

Proteins: Structure, Function, and Bioinformatics · 2025-01 · 93 (1) · 3-10

DOI: 10.1002/prot.26597 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proteins: Structure, Function, and Bioinformatics, online erschienen am 29.09.2023. Verfasst von Shiwangi Maurya und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Indian Institute of Technology, Kanpur, India. Hauptthemen laut MEDLINE: Methylamines, Limit of Detection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Trimethylamine monooxygenase ( Tmm , EC‐1.14.13.148) belongs to the family of flavin‐containing monooxygenases that oxidize trimethylamine into trimethylamine‐N‐oxide (TMAO). Conventional methods for assaying Tmm are accurate over a narrow range of substrate/product concentrations. Here we report a TMAO‐specific enzymatic assay for Tmm using polyallylamine hydrochloride (PAHCl)‐capped MnO 2 nanoparticles (PAHCl@MnO 2 ). We achieved TMAO specificity using iodoacetonitrile to remove interfering trimethylamine. The change in the concentration of TMAO is measured by observing the difference in the absorbance of 3,3′,5,5′‐tetramethylbenzidine (TMB) at 650 nm. The assay is tolerant to several interfering metal ions and other compounds. This method is more accessible and reliable than currently known methods. The limit of detection (LOD) and limit of quantitation (LOQ) are 1 μM and 10 μM, respectively, for direct TMAO measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MethylaminesLimit of DetectionPolyaminesBenzidinesSpectrophotometrySubstrate SpecificityManganese CompoundsEnzyme AssaysOxidation-Reduction

Stichwörter der Autor:innen

3,3′,5,5′‐tetramethylbenzidineMnO2 nanoparticlesParacoccus sp. DMFflavin monooxygenasestrimethylamine‐N‐oxide detection

Substanzen

MethylaminestrimethyloxaminetrimethylaminePolyaminespolyallylamineBenzidines3,3',5,5'-tetramethylbenzidineManganese Compounds

Autor:innen und Institutionen

  • Department of Chemistry, Indian Institute of Technology, Kanpur, India.

ORCID-Profile: Gurunath Ramanathan

Zitieren

APA

Maurya, S., Singh, A., & Ramanathan, G. (2025). A spectrophotometric trimethylamine monooxygenase assay. Proteins: Structure, Function, and Bioinformatics, 93(1), 3-10. https://doi.org/10.1002/prot.26597

Vancouver

Maurya S, Singh A, Ramanathan G. A spectrophotometric trimethylamine monooxygenase assay. Proteins: Structure, Function, and Bioinformatics. 2025;93(1):3-10. doi:10.1002/prot.26597

BibTeX
@article{Maurya2025,
  author = {Maurya, Shiwangi and Singh, Abhishek and Ramanathan, Gurunath},
  title = {A spectrophotometric trimethylamine monooxygenase assay},
  journal = {Proteins: Structure, Function, and Bioinformatics},
  year = {2025},
  volume = {93},
  number = {1},
  pages = {3--10},
  doi = {10.1002/prot.26597}
}
Kostenlos starten →