Spatial Distribution of Prostate Cancer Missed by MRI‐Targeted Biopsy, Effect of a Perilesional Template, and Restaging in a Radical Prostatectomy Cohort
The Prostate · 2026-08 · 86 (11) · 1216-1223
DOI: 10.1002/pros.70201 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Prostate, online erschienen am 26.05.2026. Verfasst von Ruth Himmelsbach und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Image-Guided Biopsy, Prostate. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose Systematic biopsy (SB) remains recommended in addition to MRI‐targeted biopsy (TB) because TB alone may miss clinically significant prostate cancer (sPC). We evaluated the spatial distribution of sPC and clinically insignificant prostate cancer (iPC) detected by SB in relation to MRI lesions and assessed the effect of perilesional template (PLT) in terms of cancer detection. Materials and Methods We retrospectively analyzed 1043 men who underwent combined transperineal MRI/TRUS fusion biopsy. Spatial distribution between MRI lesions and cancer‐positive SB cores was calculated. Hypothetical PLTs with 5, 10, and 15 mm were modeled. Radical prostatectomy (RP) whole‐mount histopathology served as the reference standard. Results sPC was detected in 521/1043 (50.0%) men. SB alone identified sPC in 98 patients. The mean distance to the nearest sPC core was significantly shorter than for iPC (7.8 vs. 12.4 mm; p < 0.001). Cumulative sPC detection increased up to approximately 10 mm from the lesion border and plateaued thereafter, whereas iPC detection increased linearly beyond 10 mm. A 10mm‐PLT would have detected 94.3% of all cancers and avoided 3.7% of iPC diagnoses, while missing 2.5% of sPC. Extending the margin to 15 mm did not meaningfully improve sPC detection but increased iPC detection. Use of 10mm‐PLT would have resulted in 10.5% upgrades to sPC in RP compared to 5.9% in the TB + SB cohort. Conclusions sPC is spatially concentrated near MRI lesions, whereas iPC is more widely distributed. A 10mm‐PLT captures most sPC and provides an empirical basis for the guideline‐recommended perilesional margin. Prospective validation is required before SB can be safely replaced.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany.
ORCID-Profile: Julia Franz
Zitieren
APA
Himmelsbach, R., Franz, J., Jilg, C., Gratzke, C., & Sigle, A. (2026). Spatial Distribution of Prostate Cancer Missed by MRI‐Targeted Biopsy, Effect of a Perilesional Template, and Restaging in a Radical Prostatectomy Cohort. The Prostate, 86(11), 1216-1223. https://doi.org/10.1002/pros.70201
Vancouver
Himmelsbach R, Franz J, Jilg C, Gratzke C, Sigle A. Spatial Distribution of Prostate Cancer Missed by MRI‐Targeted Biopsy, Effect of a Perilesional Template, and Restaging in a Radical Prostatectomy Cohort. The Prostate. 2026;86(11):1216-1223. doi:10.1002/pros.70201
BibTeX
@article{Himmelsbach2026,
author = {Himmelsbach, Ruth and Franz, Julia and Jilg, Cordula and Gratzke, Christian and Sigle, August},
title = {Spatial Distribution of Prostate Cancer Missed by MRI‐Targeted Biopsy, Effect of a Perilesional Template, and Restaging in a Radical Prostatectomy Cohort},
journal = {The Prostate},
year = {2026},
volume = {86},
number = {11},
pages = {1216--1223},
doi = {10.1002/pros.70201}
}
EUVIMED