Prostate Volume and PSA‐Density Estimation by Transabdominal Ultrasound: Prospective Evidence of Comparative Accuracy to MRI and Transrectal Ultrasound in Prostate Cancer Early Diagnostics
The Prostate · 2025
DOI: 10.1002/pros.70036 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Prostate, 2025. Verfasst von Liza M Kurucz und 13 weiteren Autor:innen. Beteiligte Einrichtung: Center for Early Cancer Detection, The Netherlands Cancer Institute, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Prostate-Specific Antigen, Magnetic Resonance Imaging, Prostate. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: This study received financial support from the Antoni van Leeuwenhoek Foundation..
Abstract (Originalsprache)
Background
Prostate‐specific antigen (PSA) density is an easily available predictor for clinically significant PCa. While transrectal ultrasound (TRUS) is utilized for PSA density (PSAD) estimation, transabdominal ultrasound (TAUS) is a more accessible, noninvasive alternative that can be used to decide if follow‐up diagnostics are necessary. This study aims to compare prostate volume (PV) and PSAD across TAUS, TRUS and MRI, comparing the clinical utility of TAUS and TRUS for PSAD‐based risk stratification.
Methods
Hundred and eighty men undergoing PCa diagnostics were included by collecting serum PSA, TRUS, MRI, and TAUS PV examinations. PV was calculated blindly by all operators and image quality was assessed. Agreement in PV measurements of all imaging modalities was analyzed in Bland‐Altman diagrams. PCa risk derived from PSAD TAUS and PSAD TRUS was compared against MRI outcomes in Sankey diagrams and the percentage of misclassified PCa risk was reported.
Results
After excluding 33 inadequate TAUS acquisitions, 147 patients were included. The average volume difference between TAUS and MRI was 2.5 mL (standard deviation (SD): 16.4), between TAUS and TRUS 11.5 mL (SD: 20.4), and between TRUS and MRI −9.0 mL (SD: 21.1). TAUS and TRUS underestimate PCa risk in 3%–4%, while the percentage of men with overestimated risk decreased when TAUS was used (7% vs. 13%).
Conclusions
PVs obtained with TAUS are equivalent to MRI. Still, image quality varies with experience and interobserver variability needs further exploration, ensuring generalizable outcomes. Nevertheless, TAUS represents a valid alternative for PV and PSAD estimation, enabling a patient‐friendly alternative for PCa risk assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Early Cancer Detection, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
- Department of Nanobiophysics, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands.
- Image-Guided Surgery, Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
- Department of Urology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
- Department of Urology, Erasmus MC Cancer Institute, Erasmus University Medical Centre, The Netherlands.
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
ORCID-Profile: Liza M Kurucz, Tiziano Natali, Georgios Agrotis
Förderung
- This study received financial support from the Antoni van Leeuwenhoek Foundation.
Zitieren
APA
Kurucz, L. M., Natali, T., Westerhout, S., Hagens, M., Visser, J. J., van Muilekom, E. A. M., van Kesteren, J. D., Schoots, I., Boellaard, T. N., Agrotis, G., Dashtbozorg, B., Ruers, T. J. M., van Leeuwen, P. J., & Mertens, L. S. (2025). Prostate Volume and PSA‐Density Estimation by Transabdominal Ultrasound: Prospective Evidence of Comparative Accuracy to MRI and Transrectal Ultrasound in Prostate Cancer Early Diagnostics. The Prostate. https://doi.org/10.1002/pros.70036
Vancouver
Kurucz LM, Natali T, Westerhout S, Hagens M, Visser JJ, van Muilekom EAM, et al. Prostate Volume and PSA‐Density Estimation by Transabdominal Ultrasound: Prospective Evidence of Comparative Accuracy to MRI and Transrectal Ultrasound in Prostate Cancer Early Diagnostics. The Prostate. 2025. doi:10.1002/pros.70036
BibTeX
@article{Kurucz2025,
author = {Kurucz, Liza M and Natali, Tiziano and Westerhout, Sanne and Hagens, Marias and Visser, Jeroen J and van Muilekom, Erik A M and van Kesteren, Jolien D and Schoots, Ivo and Boellaard, Thierry N and Agrotis, Georgios and Dashtbozorg, Behdad and Ruers, Theo J M and van Leeuwen, Pim J and Mertens, Laura S},
title = {Prostate Volume and PSA‐Density Estimation by Transabdominal Ultrasound: Prospective Evidence of Comparative Accuracy to MRI and Transrectal Ultrasound in Prostate Cancer Early Diagnostics},
journal = {The Prostate},
year = {2025},
doi = {10.1002/pros.70036}
}
EUVIMED