EUVIMEDEUVIMED entdecken
Crossref

Confirmation of Solid Phase Extracted Post‐Blast Explosives Residues Analyzed Using Pulsed Split Injection GC/MS

Courtney A. Cruse, Christopher A. Tipple, Mark L. Miller

Propellants, Explosives, Pyrotechnics · 2025-01 · 50 (1)

DOI: 10.1002/prep.202400184 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Propellants, Explosives, Pyrotechnics, online erschienen am 27.10.2024. Verfasst von Courtney A. Cruse und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A pulsed split injection method was developed for the improved detection of explosives using gas chromatography with mass spectrometric detection (GC/MS) with negative chemical ionization for 12 organic explosives (nitramines, nitrate esters, nitroalkanes, nitroaromatics) and electron ionization with selected ion monitoring for triacetone triperoxide (TATP). An order of magnitude increase in signal (average factor of 13) was observed for all organic explosives with the utilization of the pulsed split injection for samples processed by solid phase extraction (SPE). The method was successfully applied to post‐blast explosives residue processed by SPE and syringe filtration as a confirmatory technique following gas chromatography with electron capture detection (GC/ECD) screening. Compared to current methodologies previously reported, a decrease in the false screen rate (the number of compounds that passed the screening criteria, but not confirmed present) was achieved when employing this method. Processing of post‐blast explosives samples using SPE decreased the false screen rate from 60% to 34%, while using syringe filtration decreased the false screen rate from 73% to 51%.

Zitieren

APA

Cruse, C. A., Tipple, C. A., & Miller, M. L. (2025). Confirmation of Solid Phase Extracted Post‐Blast Explosives Residues Analyzed Using Pulsed Split Injection GC/MS. Propellants, Explosives, Pyrotechnics, 50(1). https://doi.org/10.1002/prep.202400184

Vancouver

Cruse CA, Tipple CA, Miller ML. Confirmation of Solid Phase Extracted Post‐Blast Explosives Residues Analyzed Using Pulsed Split Injection GC/MS. Propellants, Explosives, Pyrotechnics. 2025;50(1). doi:10.1002/prep.202400184

BibTeX
@article{Cruse2025,
  author = {Cruse, Courtney A. and Tipple, Christopher A. and Miller, Mark L.},
  title = {Confirmation of Solid Phase Extracted Post‐Blast Explosives Residues Analyzed Using Pulsed Split Injection GC/MS},
  journal = {Propellants, Explosives, Pyrotechnics},
  year = {2025},
  volume = {50},
  number = {1},
  doi = {10.1002/prep.202400184}
}
Kostenlos starten →