Poly(vinyl alcohol)/polyacrylamide double‐network ionic conductive hydrogel strain sensor with high sensitivity and high elongation at break
Journal of Polymer Science · 15.10.2024 · 62 (20) · 4599-4611
DOI: 10.1002/pol.20240209 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Polymer Science, online erschienen am 19.07.2024. Verfasst von Zijian Wu und 11 weiteren Autor:innen. Die Arbeit wurde bisher 72-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Key Laboratory of Electrical Insulation and Power Equipment.
Abstract (Originalsprache)
As a soft material with biocompatibility and stimulation response, ionic conductive hydrogel‐based wearable strain sensors show great potential across a wide spectrum of engineering disciplines, but their mechanical toughness is limited in practical applications. In this study, freeze‐thawing techniques were utilized to fabricate double‐network hydrogels of poly(vinyl alcohol)/polyacrylamide (PVA/PAM) with both covalent and physical cross‐linking networks. These double‐network hydrogels demonstrate excellent mechanical performance, with an elongation at break of 2253% and tensile strength of 268.2 kPa. Simultaneously, they also display a high sensitivity (Gage factor, GF = 2.32 at 0%–200% strain), achieve a rapid response time of 368 ms without the addition of extra conductive fillers or ions, stable signal transmission even after multiple cycles, and fast response to human motion detection.
Förderung
- State Key Laboratory of Electrical Insulation and Power Equipment
Zitieren
APA
Wu, Z., Liu, X., Xu, Q., Zhang, L., Abdou, S. N., Ibrahim, M. M., Zhang, J., El‐Bahy, Z. M., Guo, N., Gao, J., Weng, L., & Guo, Z. (2024). Poly(vinyl alcohol)/polyacrylamide double‐network ionic conductive hydrogel strain sensor with high sensitivity and high elongation at break. Journal of Polymer Science, 62(20), 4599-4611. https://doi.org/10.1002/pol.20240209
Vancouver
Wu Z, Liu X, Xu Q, Zhang L, Abdou SN, Ibrahim MM, et al. Poly(vinyl alcohol)/polyacrylamide double‐network ionic conductive hydrogel strain sensor with high sensitivity and high elongation at break. Journal of Polymer Science. 2024;62(20):4599-4611. doi:10.1002/pol.20240209
BibTeX
@article{Wu2024,
author = {Wu, Zijian and Liu, Xiaorui and Xu, Qi and Zhang, Liying and Abdou, Safaa N. and Ibrahim, Mohamed M. and Zhang, Jing and El‐Bahy, Zeinhom M. and Guo, Ning and Gao, Junguo and Weng, Ling and Guo, Zhanhu},
title = {Poly(vinyl alcohol)/polyacrylamide double‐network ionic conductive hydrogel strain sensor with high sensitivity and high elongation at break},
journal = {Journal of Polymer Science},
year = {2024},
volume = {62},
number = {20},
pages = {4599--4611},
doi = {10.1002/pol.20240209}
}
EUVIMED