Evaluating the efficacy of obturator cryoneurolysis for hip adductor spasticity: An observational, prospective study

Fraser MacRae iD, Mahdis Hashemi iD, Paul Winston iD

PM&R · 27.05.2026

DOI: 10.1002/pmrj.70156 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PM&R, online erschienen am 27.05.2026. Verfasst von Fraser MacRae und 2 weiteren Autor:innen. Beteiligte Einrichtung: Western University, London, Ontario, Canada. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Pacira BioSciences, Inc., Pacira BioSciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Hip adductor spasticity is a common affliction among patients with disorders of the central nervous system. Cryoneurolysis is a novel intervention for spasticity involving the application of extreme cold to a nerve. This induces axonal breakdown, relieving spasticity.

Objective

To evaluate the effect of cryoneurolysis on hip spasticity in adults.

Design

This study was an observational, single‐center, prospective cohort study.

Participants

Twenty adult patients who had been scheduled to receive cryoneurolysis for hip adductor spasticity as part of their standard treatment were included. Patients with a history of previous nerve procedures, cryoneurolysis, or surgery of obturator nerves were excluded.

Interventions

Cryoneurolysis of anterior and posterior branches of the obturator nerve was performed. Main Outcome Measures The primary outcome was spasticity severity on the Modified Ashworth Scale. Additional outcomes included passive and active ranges of motion and the goal attainment scale.

Results

There was a large reduction in Modified Ashworth Scale scores at 3 months on the right side (Wilcoxon W [ W ] = 6.0, p < .01; rank‐biserial correlation [rrb] = −0.89, 95% confidence interval [CI] = −1.00, −0.63) and the left ( W = 0.0, p < .001; rrb = −1.00, 95% CI = −1.00, −1.00). The decreases persisted at 1 year on the right ( W = 0.00, p < .001; rrb = −1.00, 95% CI = −1.00, −1.00) and the left ( W = 12.0, p < .05; rrb = −0.69, 95% CI = −1.00, −0.10). Maximum passive range of motion increased on the right side 1 year after treatment (repeated measures analysis of variance p < .05, ηp 2 = 0.14, 95% CI = 0.07–0.26]) but not on the left side ( p = .24, ηp 2 = 0.07, 95% CI = 0.04–0.21).

Conclusions

Cryoneurolysis resulted in decreased spasticity severity lasting for 1 year. Cryoneurolysis merits further investigation as a potential long‐lasting, minimally invasive, drug‐free intervention for hip adductor spasticity.

Autor:innen und Institutionen

  • Western University, London, Ontario, Canada.
  • Vancouver Island Health Authority, Victoria, British Columbia, Canada.
  • Canadian Advances in Neuro-Orthopedics for Spasticity Consortium, Kingston, Ontario, Canada.
  • University of British Columbia, Vancouver, British Columbia, Canada.

ORCID-Profile: Fraser MacRae, Mahdis Hashemi, Paul Winston

Förderung

  • Pacira BioSciences, Inc.
  • Pacira BioSciences

Zitieren

APA

MacRae, F., Hashemi, M., & Winston, P. (2026). Evaluating the efficacy of obturator cryoneurolysis for hip adductor spasticity: An observational, prospective study. PM&R. https://doi.org/10.1002/pmrj.70156

Vancouver

MacRae F, Hashemi M, Winston P. Evaluating the efficacy of obturator cryoneurolysis for hip adductor spasticity: An observational, prospective study. PM&R. 2026. doi:10.1002/pmrj.70156

BibTeX
@article{MacRae2026,
  author = {MacRae, Fraser and Hashemi, Mahdis and Winston, Paul},
  title = {Evaluating the efficacy of obturator cryoneurolysis for hip adductor spasticity: An observational, prospective study},
  journal = {PM&R},
  year = {2026},
  doi = {10.1002/pmrj.70156}
}
Kostenlos starten →