EUVIMEDEUVIMED entdecken
Crossref

Discovering PM&R: Determinants and Timing of Medical Student Interest in PM&R, A Cross‐Sectional Survey

Brett Segobiano, Other

PM&R · 2026-11 · 18 (S3)

DOI: 10.1002/pmrj.15_70259 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PM&R, online erschienen am 10.11.2026. Verfasst von Brett Segobiano und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

spinal cord injury (SCI), their accuracy remains inadequately studied.This study aimed to evaluate the accuracy in capturing directional movement from a single portable sensor placed directly in front of subject, relative to standard force plate.

Design

Controlled, cohort study.

Setting

Single site.

Participants

14 individuals with thoracic SCI (18-70 yrs old) were recruited for this study.Subjects were recruited using posted flyers, social media, and word of mouth.SCI injury levels and AIS grades were confirmed the day of entry via the International Standards for Neurological Classification of SCI exam.Subjects performed 13 dynamic seated tasks (e.g. 8 leaning with arms crossed and 5 reaching with one arm out), while being simultaneously recorded by the Kinect sensor and AMTI force plate (FP).Fifteen healthy individuals (with similar ages and genders) were collected for comparisons.

Interventions

Not applicable.Main Outcome Measures: Max excursions for each of the dynamic tasks were calculated.Accuracy of the Kinect system was compared to FP using Pearson correlation and Bland-Altman.Differences between the devices (using mean, median, standard deviation) and root mean square errors were also determined.

Results

Correlations were moderate to strong (R = 0.43 -0.89).Differences between devices indicated the Kinect slightly under-estimating forward movements by 2cm in SCI subjects (60-79% of the time), but over-estimating in the back leaning and lateral directions by 6cm.RMSE ranged from 0.15 -1.8cm.

Conclusions

Although the Kinect was generally comparable to the FP for max excursions in SCI subjects, there were offsets in the movements from the anterior-posterior plane that merit further investigation.Repositioning the Kinect to a 45 degree recording angle (instead of head on) may provide better accuracy and resolution.

Zitieren

APA

Segobiano, B., & Other (2026). Discovering PM&R: Determinants and Timing of Medical Student Interest in PM&R, A Cross‐Sectional Survey. PM&R, 18(S3). https://doi.org/10.1002/pmrj.15_70259

Vancouver

Segobiano B, Other. Discovering PM&R: Determinants and Timing of Medical Student Interest in PM&R, A Cross‐Sectional Survey. PM&R. 2026;18(S3). doi:10.1002/pmrj.15_70259

BibTeX
@article{Segobiano2026,
  author = {Segobiano, Brett and Other},
  title = {Discovering PM&R: Determinants and Timing of Medical Student Interest in PM&R, A Cross‐Sectional Survey},
  journal = {PM&R},
  year = {2026},
  volume = {18},
  number = {S3},
  doi = {10.1002/pmrj.15_70259}
}
Kostenlos starten →