Percutaneous ultrasound‐guided A1 pulley release utilizing a modified 20‐gauge spinal needle
PM&R · 2025
DOI: 10.1002/pmrj.13276 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift PM&R, 2025. Verfasst von Mark Sederberg und 3 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Sports and Orthopaedics, Lehi, Utah, USA. Hauptthemen laut MEDLINE: Trigger Finger Disorder, Needles, Ultrasonography, Interventional, Orthopedic Procedures. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Trigger finger is a common cause of hand pain. Though multiple techniques for percutaneous A1 pulley release have been described in the literature, there is a continued need for safe and effective techniques using inexpensive, familiar, and commonly found instruments. This study evaluated outcomes of percutaneous A1 pulley release performed using a novel technique with a modified 20‐gauge spinal needle and ultrasound guidance, with follow‐up outcomes at least 6 months after the procedure.
Objective
To evaluate the efficacy and safety of a novel percutaneous A1‐pulley release technique in individuals with trigger finger.
Design
Retrospective observational study.
Setting
Private practice outpatient orthopedics clinic.
Participants
Forty digits from 30 unique patients with trigger finger who underwent percutaneous A1 pulley release.
Interventions
Percutaneous ultrasound‐guided A1 pulley release performed with a modified 20‐gauge spinal needle. Main Outcome Measures The primary outcome measure was cessation of triggering. Secondary measures examined intraoperative and postoperative pain, postprocedural duration of activity limiting pain, and time to perform the procedure.
Results
Immediate cessation of triggering was achieved in all 40 digits following the procedure, with no recurrence reported at any time at an average follow‐up of 11 months (range 6–32). Patients reported returning to normal activity in 2.75 days. Only one minor complication was reported, tenosynovitis, which resolved with a corticosteroid injection.
Conclusions
Percutaneous, ultrasound‐guided A1 pulley release performed with a modified 20‐gauge spinal needle can be safely performed with good outcomes and a rapid return to normal activity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Advanced Sports and Orthopaedics, Lehi, Utah, USA.
- Department of Physical Medicine & Rehabilitation, University of Utah, Salt Lake City, Utah, USA.
- Department of Physical Medicine and Rehabilitation, The Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
- Department of Sports Medicine, US Olympic & Paralympic Committee, Colorado Springs, Colorado, USA.
- US Coalition for the Prevention of Illness and Injury in Sport, Colorado Springs, Colorado, USA.
ORCID-Profile: Mark Sederberg
Zitieren
APA
Sederberg, M., Sharma, R., Cushman, D. M., & Finnoff, J. T. (2025). Percutaneous ultrasound‐guided A1 pulley release utilizing a modified 20‐gauge spinal needle. PM&R. https://doi.org/10.1002/pmrj.13276
Vancouver
Sederberg M, Sharma R, Cushman DM, Finnoff JT. Percutaneous ultrasound‐guided A1 pulley release utilizing a modified 20‐gauge spinal needle. PM&R. 2025. doi:10.1002/pmrj.13276
BibTeX
@article{Sederberg2025,
author = {Sederberg, Mark and Sharma, Ragav and Cushman, Daniel M and Finnoff, Jonathan T},
title = {Percutaneous ultrasound‐guided A1 pulley release utilizing a modified 20‐gauge spinal needle},
journal = {PM&R},
year = {2025},
doi = {10.1002/pmrj.13276}
}
EUVIMED