EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Unspecific Molecular Adsorption (UMA) Sample Preparation Method for Bottom‐up and Whole Protein Analysis: The Foundation

Alexandre Zougman iD

PROTEOMICS · 2026

DOI: 10.1002/pmic.70149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PROTEOMICS, 2026. Verfasst von Alexandre Zougman. Beteiligte Einrichtung: Leeds Institute of Medical Research, St James's University Hospital, Leeds, UK. Hauptthemen laut MEDLINE: Proteomics, Proteins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The protein sample preparation methods for shotgun proteomics are nowadays well‐established unlike the ones for whole protein analysis. The goal of my work has been to create a simple methodology which provides a single uncomplicated sample preparation tool for these two fields. Nowadays the bulk of proteomics work is done using detergents for protein solubilization. The presented concept, which is based on unspecific adsorption of protein molecules on wide pore materials, allows for protein capture and clean‐up from solutions of the most commonly used sodium dodecyl sulfate detergent. It could also be applied to proteins in detergent‐free solutions. After the capture and clean‐up, proteins could be either cleaved for the downstream peptide analysis or eluted for the whole protein analysis. If required, the eluted whole proteins could be recaptured and cleaved into peptides. Depending on the experimental goals, the sample preparation device could be fitted with embedded proteolytic enzymes to simplify routine sample processing and/or reversed phase media for the downstream peptide or protein separation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProteomicsProteinsAdsorptionDetergentsHumansSodium Dodecyl SulfatePeptides

Substanzen

ProteinsDetergentsSodium Dodecyl SulfatePeptides

Autor:innen und Institutionen

  • Leeds Institute of Medical Research, St James's University Hospital, Leeds, UK.

ORCID-Profile: Alexandre Zougman

Zitieren

APA

Zougman, A. (2026). Unspecific Molecular Adsorption (UMA) Sample Preparation Method for Bottom‐up and Whole Protein Analysis: The Foundation. PROTEOMICS. https://doi.org/10.1002/pmic.70149

Vancouver

Zougman A. Unspecific Molecular Adsorption (UMA) Sample Preparation Method for Bottom‐up and Whole Protein Analysis: The Foundation. PROTEOMICS. 2026. doi:10.1002/pmic.70149

BibTeX
@article{Zougman2026,
  author = {Zougman, Alexandre},
  title = {Unspecific Molecular Adsorption (UMA) Sample Preparation Method for Bottom‐up and Whole Protein Analysis: The Foundation},
  journal = {PROTEOMICS},
  year = {2026},
  doi = {10.1002/pmic.70149}
}
Kostenlos starten →