Comparison of In‐Gel and SP3 Based Sample Preparation Protocols for LC‐MS/MS Based Proteomics
PROTEOMICS · 2026-07 · 26 (7) · 6-16
DOI: 10.1002/pmic.70123 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PROTEOMICS, online erschienen am 29.03.2026. Verfasst von Luisa Schwarzmüller und 5 weiteren Autor:innen. Beteiligte Einrichtung: Proteomics Core Facility, German Cancer Research Center (DKFZ), Heidelberg, Germany. Hauptthemen laut MEDLINE: Proteomics, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Proteome. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MSCoreSys.
Abstract (Originalsprache)
Sensitivity, robustness, and reproducibility of sample preparation are main determinants of data quality in bottom‐up mass spectrometry‐based proteomics. To this end, in‐gel protein clean‐up and digestion has been used for decades and is characterized by its robustness and compatibility with harsh lysis conditions. Single‐pot solid‐phase‐enhanced sample preparation (SP3) has gained substantial popularity recently and has been widely adapted as a standard workflow often replacing in‐gel digestion‐based workflows. Noteworthy, until today no direct comparison between the two workflows has been conducted. Here, we performed a systematic comparison of in‐gel and SP3 based sample preparation workflows assessing sensitivity, robustness, reproducibility, and fractionation possibilities on human cellular lysates and blood plasma. Both methods performed similarly regarding number of identified proteins, however, showed specific biases. SP3 outperformed the in‐gel workflow regarding higher sensitivity when handling limited sample amounts, especially below 5 µg of input material. In contrast, in‐gel sample preparation was superior in the identification of low molecular weight proteins. In conclusion, while SP3 is indeed the state‐of‐the‐art proteomics sample preparation method, in‐gel digestion can deliver competitive and complementary results and still has advantages in some applications, such as measurement of small proteins or when there is a need for protein‐level separation, e. g. in plasma samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Proteomics Core Facility, German Cancer Research Center (DKFZ), Heidelberg, Germany.
- Division Molecular Genome Analysis, German Cancer Research Center (DKFZ), Heidelberg, Germany.
- Faculty of Biosciences, University Heidelberg, Heidelberg, Germany.
- Proteomics Core Facility, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Förderung
- MSCoreSys
Zitieren
APA
Schwarzmüller, L., Frey, D., Zadora, P., Schneider, M., Wiemann, S., & Helm, D. (2026). Comparison of In‐Gel and SP3 Based Sample Preparation Protocols for LC‐MS/MS Based Proteomics. PROTEOMICS, 26(7), 6-16. https://doi.org/10.1002/pmic.70123
Vancouver
Schwarzmüller L, Frey D, Zadora P, Schneider M, Wiemann S, Helm D. Comparison of In‐Gel and SP3 Based Sample Preparation Protocols for LC‐MS/MS Based Proteomics. PROTEOMICS. 2026;26(7):6-16. doi:10.1002/pmic.70123
BibTeX
@article{Schwarzmller2026,
author = {Schwarzmüller, Luisa and Frey, Dario and Zadora, Piotr and Schneider, Martin and Wiemann, Stefan and Helm, Dominic},
title = {Comparison of In‐Gel and SP3 Based Sample Preparation Protocols for LC‐MS/MS Based Proteomics},
journal = {PROTEOMICS},
year = {2026},
volume = {26},
number = {7},
pages = {6--16},
doi = {10.1002/pmic.70123}
}
EUVIMED