EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Predicting intrauterine vacuum‐induced postpartum hemorrhage‐control device treatment success

Marcela C Smid, James Li, Joseph R Biggio iD, Kara M Rood iD, Hyagriv N Simhan, Patricia I Carney, Damien Croft, Candice Yong, Dena Goffman, RUBY Investigators

Pregnancy · 2026-03 · 2 (2)

DOI: 10.1002/pmf2.70222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pregnancy, online erschienen am 27.02.2026. Verfasst von Marcela C Smid und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology University of Utah Health Salt Lake City Utah USA. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Organon BioSciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To identify predictors of postpartum hemorrhage (PPH) treatment success with the JADA intrauterine vacuum‐induced hemorrhage‐control device in post‐market settings.

Methods

We performed a retrospective cohort study of PPH managed using the JADA system across 16 centers in the United States (NCT04995887). Treatment success was defined as no treatment escalation or PPH recurrence after device placement. Multivariable logistic regression was used to determine significant predictors of PPH treatment success with a stepwise model selection technique. Selection of the best performing model was determined using area under the receiver operating characteristic (AUC) curves, Akaike information criterion (AIC), and data completeness. In exploratory analyses, we assessed differences in treatment success by cause of bleeding and difference in time to device insertion by self‐reported race, including an interaction term between race and insertion time.

Results

From October 2020 to March 2022, 800 individuals had PPH managed with the JADA device. Most individuals delivered vaginally ( n = 530, 66.3%), self‐identified as White ( n = 463, 58.7%), and had a body mass index at delivery ≥35 kg/m 2 ( n = 322, 40.2%). Cumulative blood loss (CBL) ≥1000 mL before device insertion occurred in 59.5% of individuals, and 65.9% experienced isolated uterine atony. Overall, the treatment success rate was 89.5%, varying across the top predictors. Device success ranged from 90.0% to 94.3% when CBL was

Schlagwörter

Stichwörter der Autor:innen

postpartum hemorrhagetreatment successvacuum hemorrhage‐control device

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology University of Utah Health Salt Lake City Utah USA.
  • Department of Obstetrics and Gynecology Organon & Co. Jersey City New Jersey USA.
  • Department of Obstetrics and Gynecology Ochsner Health New Orleans Louisiana USA.
  • The Ohio State University-Wexner Medical Center Columbus Ohio USA.
  • University of Pittsburgh Medical Center-Magee Womens Hospital Pittsburgh Pennsylvania USA.
  • Columbia University Irving Medical Center & New York Presbyterian Hospital New York New York USA.

ORCID-Profile: Joseph R Biggio, Kara M Rood

Förderung

  • Organon BioSciences

Zitieren

APA

Smid, M. C., Li, J., Biggio, J. R., Rood, K. M., Simhan, H. N., Carney, P. I., Croft, D., Yong, C., Goffman, D., & RUBY Investigators (2026). Predicting intrauterine vacuum‐induced postpartum hemorrhage‐control device treatment success. Pregnancy, 2(2). https://doi.org/10.1002/pmf2.70222

Vancouver

Smid MC, Li J, Biggio JR, Rood KM, Simhan HN, Carney PI, et al. Predicting intrauterine vacuum‐induced postpartum hemorrhage‐control device treatment success. Pregnancy. 2026;2(2). doi:10.1002/pmf2.70222

BibTeX
@article{Smid2026,
  author = {Smid, Marcela C and Li, James and Biggio, Joseph R and Rood, Kara M and Simhan, Hyagriv N and Carney, Patricia I and Croft, Damien and Yong, Candice and Goffman, Dena and RUBY Investigators, RUBY Investigators},
  title = {Predicting intrauterine vacuum‐induced postpartum hemorrhage‐control device treatment success},
  journal = {Pregnancy},
  year = {2026},
  volume = {2},
  number = {2},
  doi = {10.1002/pmf2.70222}
}
Kostenlos starten →