EUVIMEDEUVIMED entdecken
Crossref

Continuous Preparation of Core‐Shell Capsules for CO 2 Detection Using Photosensitive Polymeric Resins

Alireza Lotfi, Mahshid Maroufkhani, Behzad Pourabbas

Polymer Engineering & Science · 2026-06 · 66 (6) · 3915-3922

DOI: 10.1002/pen.70403 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymer Engineering & Science, online erschienen am 20.03.2026. Verfasst von Alireza Lotfi und 2 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Core–shell CO 2 ‐detector capsules were developed using a cost‐effective, energy‐efficient, and scalable production method. The polymer capsules consisted of liquid potassium carbonate cores and highly permeable UV‐curable acrylate resin shells, were fabricated through a continuous injection process, and allowed rapid and controlled CO 2 uptake and release during repeated absorption–desorption cycles while maintaining the capacity and selectivity of liquid sorbents with a high surface area to volume ratio. A custom UV box was employed as an innovative curing system to ensure uniform capsule formation. The capsules produced under these conditions exhibited an outer diameter of 2.95–3.10 mm and a shell thickness of 0.09–0.37 mm. During CO 2 exposure, the capsules demonstrated reversible absorption–desorption behavior and after approximately 100 s, a visible color transition from blue to yellow occurred due to a pH decrease in the core caused by CO 2 absorption. Also, when capsules were placed under vacuum, the reaction was reversed and they regenerated, returning to their original blue color. The developed method offered a simple and scalable alternative to conventional microfluidic encapsulation, producing uniform capsules with fast response and easy regeneration which are suitable for low‐cost and reusable optical CO 2 sensors.

Zitieren

APA

Lotfi, A., Maroufkhani, M., & Pourabbas, B. (2026). Continuous Preparation of Core‐Shell Capsules for CO 2 Detection Using Photosensitive Polymeric Resins. Polymer Engineering & Science, 66(6), 3915-3922. https://doi.org/10.1002/pen.70403

Vancouver

Lotfi A, Maroufkhani M, Pourabbas B. Continuous Preparation of Core‐Shell Capsules for CO 2 Detection Using Photosensitive Polymeric Resins. Polymer Engineering & Science. 2026;66(6):3915-3922. doi:10.1002/pen.70403

BibTeX
@article{Lotfi2026,
  author = {Lotfi, Alireza and Maroufkhani, Mahshid and Pourabbas, Behzad},
  title = {Continuous Preparation of Core‐Shell Capsules for CO 2 Detection Using Photosensitive Polymeric Resins},
  journal = {Polymer Engineering & Science},
  year = {2026},
  volume = {66},
  number = {6},
  pages = {3915--3922},
  doi = {10.1002/pen.70403}
}
Kostenlos starten →