Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study

Xiaoyu Xiong iD, Feng Xu, Wei Qiu, Shaojun Li, Chengjun Liu iD

Pediatric Discovery · 2025

DOI: 10.1002/pdi3.2505 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Discovery, 2025. Verfasst von Xiaoyu Xiong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Intensive Care Unit Children's Hospital of Chongqing Medical University Chongqing China. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to compare the efficiencies of three noninvasive technologies in monitoring the perioperative hemodynamics of children with congenital heart disease (CHD) including ventricular septal defects with or without atrial septal defects. Three noninvasive technologies included transthoracic echocardiography (TTE), electrical cardiometry (EC), and vasoactive inotropic score (VIS). Parameters included left ventricular ejection fraction (LVEF) and cardiac index (cardiac index monitored by ultrasound, uCI) in TTE, cardiac index (cardiac index monitored by electrical cardiometry, eCI) and systemic vascular resistance index (SVRI) in EC, and VIS. Seventy‐four children were eligible. Three types of adverse events (AEs) related to disease activity and prognosis were observed, including cardio‐pulmonary resuscitation in five cases (5/74, 6.76%), hypoxic‐ischemic brain damage in four cases (4/74, 5.41%) and hemopurification in four cases (4/74, 5.41%). Except for LVEF, eight parameters (VISmax [maximum VIS], VISmea [mean VIS], uCImea [mean uCI], uCImin [minimum uCI], eCImea [mean eCI], eCImin [minimum eCI], SVRImea [mean SVRI], and SVRImin [minimum SVRI]) showed predictive value for any AE ( p < 0.05). VISmea, uCImea, and eCImea demonstrated the highest accuracy and linear associations (AUROC > 0.9, p = 0.00). Linear associations also existed between the three groups of parameters and the duration of mechanical ventilation (MV) and the length of stay (LOS) in the intensive care unit (ICU). The duration of MV and the LOS in the ICU increased as VISmea rose, or uCImea and eCImea fell ( p < 0.05). LVEF in TTE could not predict any AE ( p > 0.05) and not fully reflect the cardiovascular function. Therefore, most parameters obtained in TTE, EC, and VIS can reflect the perioperative hemodynamics of children with CHD, with VISmea, uCImea, and eCImea being most accurate.

Schlagwörter

Stichwörter der Autor:innen

congenital heart diseaseechocardiographyelectrical cardiometryhemodynamicsvasoactive inotropic score

Autor:innen und Institutionen

  • Department of Pediatric Intensive Care Unit Children's Hospital of Chongqing Medical University Chongqing China.
  • National Clinical Research Center for Child Health and Disorders Chongqing China.
  • Ministry of Education Key Laboratory of Child Development and Disorders Chongqing China.
  • China International Science and Technology Cooperation Base of Child Development and Critical Disorders Chongqing China.
  • Chongqing Key Laboratory of Pediatrics Chongqing China.
  • Department of Emergency Children's Hospital of Chongqing Medical University Chongqing China.

ORCID-Profile: Xiaoyu Xiong, Chengjun Liu

Zitieren

APA

Xiong, X., Xu, F., Qiu, W., Li, S., & Liu, C. (2025). Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study. Pediatric Discovery. https://doi.org/10.1002/pdi3.2505

Vancouver

Xiong X, Xu F, Qiu W, Li S, Liu C. Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study. Pediatric Discovery. 2025. doi:10.1002/pdi3.2505

BibTeX
@article{Xiong2025,
  author = {Xiong, Xiaoyu and Xu, Feng and Qiu, Wei and Li, Shaojun and Liu, Chengjun},
  title = {Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study},
  journal = {Pediatric Discovery},
  year = {2025},
  doi = {10.1002/pdi3.2505}
}
Kostenlos starten →