EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of fetal fraction measurements in a single‐nucleotide polymorphism‐based noninvasive prenatal test

Peter Benn iD, Jingwen Zhang, Daniel Lyons, Wenbo Xu, Samantha Leonard, Zachary Demko iD

Prenatal Diagnosis · 2024

DOI: 10.1002/pd.6634 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Prenatal Diagnosis, 2024. Verfasst von Peter Benn und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Connecticut Health Center, Farmington, Connecticut, USA. Hauptthemen laut MEDLINE: Polymorphism, Single Nucleotide, Noninvasive Prenatal Testing, Cell-Free Nucleic Acids. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natera Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Noninvasive prenatal testing (NIPT) for fetal aneuploidy relies on the analysis of fetoplacental cell‐free DNA (cfDNA) found in maternal plasma. A minimum cfDNA fetal fraction (FF) is required for reliable test performance, but some methods may have suboptimal accuracy for FF measurement. This study investigated the accuracy of a single‐nucleotide polymorphism‐ (SNP‐) based NIPT method to assess FF.

Methods

FF measurements using SNP‐based NIPT in consecutive samples from singleton male pregnancies were compared with FF measured using a “gold standard” Y‐chromosome method.

Results

In a cohort of 106,846 samples, the SNP‐based FF method showed a standard deviation (SD) of 0.42%. Compared to the Y chromosome FF method, a correlation coefficient, r , of 0.995, and bias of 0.17% were observed. The SD was not substantially different across specific FF ranges or for samples with high‐risk NIPT results.

Conclusions

The SNP‐based NIPT method estimates FF with good accuracy, with a SD three to eight times better than other NIPT methods (0.42% vs. 1.3%–3.4%). FF is an important quality control parameter and should be routinely reported as part of NIPT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polymorphism, Single NucleotideNoninvasive Prenatal TestingCell-Free Nucleic AcidsHumansFemalePregnancyMaleAdultFetusAneuploidy

Substanzen

Cell-Free Nucleic Acids

Autor:innen und Institutionen

  • University of Connecticut Health Center, Farmington, Connecticut, USA.
  • Natera, Inc., Austin, Texas, USA.

ORCID-Profile: Peter Benn, Zachary Demko

Förderung

  • Natera Inc

Zitieren

APA

Benn, P., Zhang, J., Lyons, D., Xu, W., Leonard, S., & Demko, Z. (2024). Accuracy of fetal fraction measurements in a single‐nucleotide polymorphism‐based noninvasive prenatal test. Prenatal Diagnosis. https://doi.org/10.1002/pd.6634

Vancouver

Benn P, Zhang J, Lyons D, Xu W, Leonard S, Demko Z. Accuracy of fetal fraction measurements in a single‐nucleotide polymorphism‐based noninvasive prenatal test. Prenatal Diagnosis. 2024. doi:10.1002/pd.6634

BibTeX
@article{Benn2024,
  author = {Benn, Peter and Zhang, Jingwen and Lyons, Daniel and Xu, Wenbo and Leonard, Samantha and Demko, Zachary},
  title = {Accuracy of fetal fraction measurements in a single‐nucleotide polymorphism‐based noninvasive prenatal test},
  journal = {Prenatal Diagnosis},
  year = {2024},
  doi = {10.1002/pd.6634}
}
Kostenlos starten →