EUVIMEDEUVIMED entdecken
Crossref

Comparative Study on the Effect of Mono‐ and Bis‐Furan Crosslinkers on PMMA Polymers Modified Glassy Carbon Electrode for Unsafe Mercury Ion Detection

Nada Tashkandi, Bayan Alghamdi, Md Mahmud Alam, Effat A. Bahaidarah, Dalal Alezi, Fatmah. M. Alshareef, Mohammed Muzibur Rahman, Nazeeha S. Alkayal

Polymers for Advanced Technologies · 2026-11 · 37 (11)

DOI: 10.1002/pat.70804 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers for Advanced Technologies, online erschienen am 23.11.2026. Verfasst von Nada Tashkandi und 7 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Gefördert von: King Abdulaziz University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, a comparative study has been done between two novel highly cross‐linked polymers based on poly(methyl methacrylate) (PMMA) using two furan‐based cross‐linking agents, 2,5‐bis(aminomethyl)furan (BAF) and difurfurylamine (DFA), to investigate how the type and loading of crosslinker influence the properties and the sensing applications of the resulting polymers. The structural, morphological, and thermal properties of the synthesized cross‐linked polymers (BAF–PMMA and DFA–PMMA) were investigated using Fourier transform infrared spectroscopy (FT‐IR), scanning electron microscopy (SEM), X‐ray diffraction (XRD), and thermogravimetric analysis (TGA). The results revealed significant improvements in the amorphous nature, surface porosity, and thermal stability of PMMA upon cross‐linking, emphasizing the critical role of the crosslinker's aromatic content and loading. In addition, the electrochemical sensing performance of DFA–PMMA was investigated for Hg 2+ detection. The fabricated sensor (DFA–PMMA 5 /GCE) exhibits an impressive linear dynamic range (LDR) from 0.1 mM to 0.1 nM, with a detection limit (DL) as low as 93.75 pM toward Hg 2+ ions. Moreover, it demonstrates a high sensitivity of 94.9367 μAμM −1 cm −2 , enabling precise detection of trace concentrations of Hg 2+ . The sensor's reproducibility and stability are found to be highly appreciable, ensuring reliable performance over extended use. This sensor shows considerable potential for environmental and analytical applications where low‐level mercury detection is crucial.

Förderung

  • King Abdulaziz University

Zitieren

APA

Tashkandi, N., Alghamdi, B., Alam, M. M., Bahaidarah, E. A., Alezi, D., Alshareef, F. M., Rahman, M. M., & Alkayal, N. S. (2026). Comparative Study on the Effect of Mono‐ and Bis‐Furan Crosslinkers on PMMA Polymers Modified Glassy Carbon Electrode for Unsafe Mercury Ion Detection. Polymers for Advanced Technologies, 37(11). https://doi.org/10.1002/pat.70804

Vancouver

Tashkandi N, Alghamdi B, Alam MM, Bahaidarah EA, Alezi D, Alshareef FM, et al. Comparative Study on the Effect of Mono‐ and Bis‐Furan Crosslinkers on PMMA Polymers Modified Glassy Carbon Electrode for Unsafe Mercury Ion Detection. Polymers for Advanced Technologies. 2026;37(11). doi:10.1002/pat.70804

BibTeX
@article{Tashkandi2026,
  author = {Tashkandi, Nada and Alghamdi, Bayan and Alam, Md Mahmud and Bahaidarah, Effat A. and Alezi, Dalal and Alshareef, Fatmah. M. and Rahman, Mohammed Muzibur and Alkayal, Nazeeha S.},
  title = {Comparative Study on the Effect of Mono‐ and Bis‐Furan Crosslinkers on PMMA Polymers Modified Glassy Carbon Electrode for Unsafe Mercury Ion Detection},
  journal = {Polymers for Advanced Technologies},
  year = {2026},
  volume = {37},
  number = {11},
  doi = {10.1002/pat.70804}
}
Kostenlos starten →