Beobachtungsstudie in der Zeitschrift Pediatric Anesthesia, 2026. Verfasst von Xiang Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Peking University School and Hospital of Stomatology, Beijing, China. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Dental Care for Children. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: the Young Clinical Research Fund of the Chinese Stomatological Association, Program for Health Technologies Promotion of National Center Stomatology.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
The challenges of nasotracheal intubation (NTI) often arise from the misalignment of the oral, pharyngeal, and laryngeal axes. We sought to assess the success and complication rate of an economically reusable J‐shaped stainless‐steel guidewire for NTI during dental treatment in children. Materials and Methods Pediatric patients undergoing dental treatment under general anesthesia who were nasally intubated during January 2016–December 2023 were retrospectively analyzed. The following variables were collected: details of relative position between endotracheal tube (ETT) tip and glottis, peri‐intubation vital signs, and incidence of related complications. The primary observation indicator was the bullseye probability, defined as the probability of the ETT directly aligning with the glottis after glottic exposure.
Results
Data were obtained from 692 pediatric patients. The bullseye probability was 49.4%. The probability of ETT tip pointing toward the tongue base was 11.3%, and the probability of ETT tip pointing toward the esophageal entrance was 1.9%. The probability of ETT tip being at the same horizontal plane with glottis was 86.8%. Additional assistance was required to advance the tube smoothly in 48.4% of cases. The total intubation time was 63.1 (Q1–Q3, 54.3–72.3) s with a 100% overall success rate. The incidence of severe lip and mucosal trauma was 0.7%.
Conclusions
The J‐shaped stainless‐steel guidewire is a suitable and economic auxiliary tool to assist NTI for outpatient dental procedures in children. The occurrence of severe lip and mucosal trauma was lower than reported in other studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Peking University School and Hospital of Stomatology, Beijing, China.
- Department of Pediatric Dentistry, Peking University Hospital of Stomatology First Clinical Division, Beijing, China.
ORCID-Profile: Yun Liu
Förderung
- the Young Clinical Research Fund of the Chinese Stomatological Association
- Program for Health Technologies Promotion of National Center Stomatology
Zitieren
APA
Zhang, X., Gao, L., Jiang, X., & Liu, Y. (2026). J‐Shaped Guidewire‐Assisted Nasotracheal Intubation in the Dental Treatment of Children—A Retrospective, Observational Study. Pediatric Anesthesia. https://doi.org/10.1002/pan.70108
Vancouver
Zhang X, Gao L, Jiang X, Liu Y. J‐Shaped Guidewire‐Assisted Nasotracheal Intubation in the Dental Treatment of Children—A Retrospective, Observational Study. Pediatric Anesthesia. 2026. doi:10.1002/pan.70108
BibTeX
@article{Zhang2026,
author = {Zhang, Xiang and Gao, Ling and Jiang, Xia and Liu, Yun},
title = {J‐Shaped Guidewire‐Assisted Nasotracheal Intubation in the Dental Treatment of Children—A Retrospective, Observational Study},
journal = {Pediatric Anesthesia},
year = {2026},
doi = {10.1002/pan.70108}
}
EUVIMED