EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

Randomized comparison of lipid‐containing and non‐lipid‐containing artificial tears on tear film dynamics over a 3‐month period

Jennifer E Ding iD, Anisha Pradhan, Dorothy K Ma, Andrea J FazioLiu, Sarah M Chang, Andrew D Graham, Devin J Leung, Ryan S Wu, Yixiu Zhou, Tatyana Svitova, Thao N Yeh, Meng C Lin

Optometry and Vision Science · 2026

DOI: 10.1002/ovs2.70084 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Optometry and Vision Science, 2026. Verfasst von Jennifer E Ding und 11 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Research Center, School of Optometry, University of California, Berkeley, California, USA. Hauptthemen laut MEDLINE: Tears, Lipids, Lubricant Eye Drops, Dry Eye Syndromes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Alcon Research Institute, University of California Berkeley, UCB-CRC Unrestricted Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To study the effects of a lipid‐containing artificial tear (AT) and a non‐lipid‐containing AT on tear film dynamics over a 3‐month period.

Methods

Subjects with low lipid layer thickness were randomized to lipid‐containing or non‐lipid‐containing ATs for 3 months. At each visit Ocular Surface Disease Index (OSDI), LipiView, non‐invasive and fluorescein tear breakup times, tear lipid layer and aqueous film recordings with EasyTear View+, and corneal staining assessment were performed. Lipid layer thickness and tear thinning rate were calculated using custom LabView programs. Mixed effects models were used to analyze relationships among variables.

Results

Thirty nine subjects completed the study. Mean EasyTear View+ lipid layer thickness with non‐lipid‐containing AT decreased from baseline (65.1 [61.0, 69.2] nm) to 3 months (58.0 [53.4, 62.7] nm, p = 0.012), whereas mean lipid layer thickness with the lipid‐containing AT remained stable (baseline = 59.0 [53.6, 64.4] nm, 3 months = 62.4 [56.1, 68.7] nm, p = 0.30). There was a significant difference in lipid layer thickness change from baseline to 3 months between the lipid‐containing (3.4 nm) and non‐lipid‐containing ATs (−7.1 nm, p = 0.014). Tear thinning rate with the non‐lipid‐containing AT was faster at 3 months (baseline = 3.01 [2.21, 3.81]%/sec, 3 months = 4.78 [3.62, 5.94]%/sec, p = 0.008), but remained stable with the lipid‐containing AT (baseline = 2.84 [1.93, 3.76]%/sec, 3 months = 2.93 [2.15, 3.70]%/sec, p = 0.84). The increase in tear thinning rate from baseline was greater with the non‐lipid‐containing (1.77%/sec) than the lipid‐containing AT (0.09%/sec, p = 0.019). Fluorescein tear breakup time with the non‐lipid‐containing AT remained stable at 3 months (4.70 [4.14, 5.25] sec) versus baseline (4.23 [3.48, 4.99] sec, p = 0.26), whereas fluorescein tear breakup time with the lipid‐containing AT was longer at 3 months (6.33 [4.85, 7.82] sec) versus baseline (4.44 [3.66, 5.22] sec, p = 0.029). There were no significant changes in OSDI score, LipiView lipid layer thickness, non‐invasive tear breakup time or corneal staining grade over the 3‐month period.

Conclusions

Patients with lipid deficiency may benefit from lipid‐containing AT over the non‐lipid‐containing AT to stabilize tear lipid thickness and minimize tear thinning while increasing tear breakup time. Trial Registration This study was registered at ClinicalTrials.gov (#NCT05705518) on the date of January 20, 2023.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TearsLipidsLubricant Eye DropsDry Eye SyndromesCorneaHumansFemaleMaleTime FactorsMiddle AgedFollow-Up StudiesAdult

Substanzen

LipidsLubricant Eye Drops

Autor:innen und Institutionen

  • Clinical Research Center, School of Optometry, University of California, Berkeley, California, USA.
  • Vision Science Graduate Group, University of California, Berkeley, California, USA.
  • Alcon Vision, LLC, Fort Worth, Texas, USA.

ORCID-Profile: Jennifer E Ding

Förderung

  • Alcon Research Institute
  • University of California Berkeley
  • UCB-CRC Unrestricted Fund
  • Roberta J. Smith Research Fund

Zitieren

APA

Ding, J. E., Pradhan, A., Ma, D. K., FazioLiu, A. J., Chang, S. M., Graham, A. D., Leung, D. J., Wu, R. S., Zhou, Y., Svitova, T., Yeh, T. N., & Lin, M. C. (2026). Randomized comparison of lipid‐containing and non‐lipid‐containing artificial tears on tear film dynamics over a 3‐month period. Optometry and Vision Science. https://doi.org/10.1002/ovs2.70084

Vancouver

Ding JE, Pradhan A, Ma DK, FazioLiu AJ, Chang SM, Graham AD, et al. Randomized comparison of lipid‐containing and non‐lipid‐containing artificial tears on tear film dynamics over a 3‐month period. Optometry and Vision Science. 2026. doi:10.1002/ovs2.70084

BibTeX
@article{Ding2026,
  author = {Ding, Jennifer E and Pradhan, Anisha and Ma, Dorothy K and FazioLiu, Andrea J and Chang, Sarah M and Graham, Andrew D and Leung, Devin J and Wu, Ryan S and Zhou, Yixiu and Svitova, Tatyana and Yeh, Thao N and Lin, Meng C},
  title = {Randomized comparison of lipid‐containing and non‐lipid‐containing artificial tears on tear film dynamics over a 3‐month period},
  journal = {Optometry and Vision Science},
  year = {2026},
  doi = {10.1002/ovs2.70084}
}
Kostenlos starten →