EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Agreement between ganglion cell‐inner plexiform layer metrics from widefield optical coherence tomography and Goldmann II, III, and V in glaucoma

Janelle Tong iD, Jack Phu, David Alonso-Caneiro, Jason Kugelman, Michael Kalloniatis iD, Ashish Agar, Minas Coroneo, Sieu Khuu

Optometry and Vision Science · 2026-07 · 103 (7)

DOI: 10.1002/ovs2.70079 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Optometry and Vision Science, online erschienen am 27.06.2026. Verfasst von Janelle Tong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center for Eye Health, University of New South Wales, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Retinal Ganglion Cells, Visual Fields, Glaucoma. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health and Medical Research Council, Australian Government Research Training Program Scholarship, Guide Dogs NSW/ACT provided a PhD scholarship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare concordance between ganglion cell‐inner plexiform layer metrics acquired using widefield optical coherence tomography (OCT) and visual function assessed using Goldmann (G) II, III, and V stimulus sizes, in turn evaluating the role of spatial summation properties in binary classification of visual field (VF) results.

Methods

Eighty three glaucoma and 34 healthy participants underwent widefield OCT scans, segmented to generate ganglion cell‐inner plexiform layer measurements, and 24‐2 VF assessment using GII, GIII, and GV in full threshold mode. Accuracy was assessed using mean weighted absolute error and 95% prediction interval width from mixed effects models between ganglion cells per stimulus area estimated from ganglion cell‐inner plexiform layer thicknesses and VF thresholds compared using mixed effects models and post hoc analyses of estimated marginal means.

Results

Across healthy and glaucoma eyes, mean weighted absolute error and 95% prediction interval widths were smallest with GV ( p < 0.0001), suggesting the least model variability with GV. With VF locations in glaucoma cohort subclassified into VF nondefective and VF defective, although significant differences in mean weighted absolute error and 95% prediction interval widths were noted within stimulus sizes ( p < 0.0001), larger values indicating poorer model accuracy were noted in glaucoma VF defective locations relative to both healthy and VF nondefective models. Larger mean weighted absolute errors and 95% prediction interval widths were observed with increasing disease stage in VF defective locations across all stimulus sizes ( p < 0.0001).

Conclusions

Overall, structure–function models in healthy eyes and VF nondefective locations were similar across all stimulus sizes, but larger deviations were observed in VF defective locations and with worsening glaucoma stage. Our findings suggest that GIII sufficiently balances measurement variability and VF defect detection, but that disease stage‐specific variations in the structure‐function relationship exist and the ability to monitor VF defect progression over time is poor regardless of stimulus size.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceRetinal Ganglion CellsVisual FieldsGlaucomaVisual Field TestsNerve FibersHumansFemaleMaleIntraocular PressureMiddle AgedAged

Autor:innen und Institutionen

  • Center for Eye Health, University of New South Wales, Sydney, New South Wales, Australia.
  • School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
  • School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia.
  • National Health and Medical Research Council Clinical Trials Centre, University of Sydney, Sydney, New South Wales, Australia.
  • Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia.
  • Concord Clinical School, Concord Repatriation General Hospital, Sydney, New South Wales, Australia.

ORCID-Profile: Janelle Tong, Michael Kalloniatis

Förderung

  • National Health and Medical Research Council
  • Australian Government Research Training Program Scholarship
  • Guide Dogs NSW/ACT provided a PhD scholarship
  • Centre for Eye Health

Zitieren

APA

Tong, J., Phu, J., Alonso-Caneiro, D., Kugelman, J., Kalloniatis, M., Agar, A., Coroneo, M., & Khuu, S. (2026). Agreement between ganglion cell‐inner plexiform layer metrics from widefield optical coherence tomography and Goldmann II, III, and V in glaucoma. Optometry and Vision Science, 103(7). https://doi.org/10.1002/ovs2.70079

Vancouver

Tong J, Phu J, Alonso-Caneiro D, Kugelman J, Kalloniatis M, Agar A, et al. Agreement between ganglion cell‐inner plexiform layer metrics from widefield optical coherence tomography and Goldmann II, III, and V in glaucoma. Optometry and Vision Science. 2026;103(7). doi:10.1002/ovs2.70079

BibTeX
@article{Tong2026,
  author = {Tong, Janelle and Phu, Jack and Alonso-Caneiro, David and Kugelman, Jason and Kalloniatis, Michael and Agar, Ashish and Coroneo, Minas and Khuu, Sieu},
  title = {Agreement between ganglion cell‐inner plexiform layer metrics from widefield optical coherence tomography and Goldmann II, III, and V in glaucoma},
  journal = {Optometry and Vision Science},
  year = {2026},
  volume = {103},
  number = {7},
  doi = {10.1002/ovs2.70079}
}
Kostenlos starten →