EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

At‐home visual acuity in children using a custom iPhone application compared with standardized in‐office visual acuity testing

Tawna L Roberts, Erick D Bothun, Yufeng Zhu, Robert J Henderson, Nicole M Boyle, David A Leske, Sarah R Hatt, Suzanne M Wernimont, Carrie E Marino, Aparna Raghuram, Vivian M Manh, Jillian M Youngerman und 18 weitere

Optometry and Vision Science · 2026-04 · 103 (4)

DOI: 10.1002/ovs2.70040 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Optometry and Vision Science, online erschienen am 30.04.2026. Verfasst von Tawna L Roberts und 29 weiteren Autor:innen. Beteiligte Einrichtung: Spencer Center for Vision Research, Byers Eye Institute at Stanford University, Palo Alto, California, USA. Hauptthemen laut MEDLINE: Visual Acuity, Mobile Applications, Vision Tests, Smartphone. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, National Eye Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To validate a custom smartphone application for at‐home visual acuity (VA) measurement in children.

Methods

A total of 452 children aged 3–17.5 years participated. Certified examiners measured in‐office test–retest VA (logMAR) using gold‐standard Amblyopia Treatment Study HOTV (3‐to‐6‐year‐olds, younger cohort) or electronic Early Treatment of Diabetic Retinopathy Study (7‐to‐17.5‐year‐olds, older cohort) protocols at 3–4.5 m and app‐based VA at 1.5 m. Caregivers measured at‐home app‐based VA at 1.5 m.

Results

Comparing at‐home app‐based with gold‐standard VA, in eyes 20/40 or better, 95% (143/151) and 93% (91/98) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = −0.03, older = −0.04; 95% limits‐of‐agreement half‐width (LOA): younger = ±0.26, older = ±0.22). In eyes 20/50 or worse, 66% (42/64) and 75% (76/101) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = 0.11, older = 0.13, LOA: younger = ±0.50, older = ±0.51). Comparing in‐office app‐based VA with gold‐standard VA, in eyes 20/40 or better, 98% (160/164) and 94% (99/105) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = −0.03, older = −0.03; LOA: younger = ±0.22; older = ±0.24). In eyes 20/50 or worse, 85% (60/71) and 91% (101/111) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = 0.04; older = 0.04; LOA: younger = ±0.39; older = ±0.24). For gold‐standard test–retest, in eyes 20/40 or better, 99% (163/164) and 99% (104/105) of the younger and older cohorts had retest within 2 lines, respectively (mean differences: younger = 0.00; older = 0.01; LOA: younger = ±0.17; older = ±0.11). For 20/50 or worse, 92% (66/72) and 100% (111/111) in the younger and older cohorts were within 2 lines, respectively (mean differences: younger = 0.01; older = 0.02; LOA: younger = ±0.35; older = ±0.15).

Conclusions

Our app demonstrated good concordance with the gold standard at home and in the office for eyes with VA of 20/40 or better. However, concordance decreased considerably for eyes with VA 20/50 or worse, particularly at home.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityMobile ApplicationsVision TestsSmartphoneHumansChildMaleChild, PreschoolAdolescentFemaleReproducibility of Results

Autor:innen und Institutionen

  • Spencer Center for Vision Research, Byers Eye Institute at Stanford University, Palo Alto, California, USA.
  • Mayo Clinic, Rochester, Minnesota, USA.
  • Jaeb Center for Health Research, Tampa, Florida, USA.
  • Rino Enterprises, LLC, St. Louis, Missouri, USA.
  • Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Seattle Children's Hospital, Seattle, Washington, USA.

ORCID-Profile: Wesley T Beaulieu, Raymond T Kraker

Förderung

  • NEI NIH HHS
  • National Eye Institute

Zitieren

APA

Roberts, T. L., Bothun, E. D., Zhu, Y., Henderson, R. J., Boyle, N. M., Leske, D. A., Hatt, S. R., Wernimont, S. M., Marino, C. E., Raghuram, A., Manh, V. M., Youngerman, J. M., Qayum, J. N., Srinivasan, G., Titelbaum, J. R., Crouch, E. R., Colburn, J. D., Esposito, C. A., Zeto, V. L., …, & Pediatric Eye Disease Investigator Group (2026). At‐home visual acuity in children using a custom iPhone application compared with standardized in‐office visual acuity testing. Optometry and Vision Science, 103(4). https://doi.org/10.1002/ovs2.70040

Vancouver

Roberts TL, Bothun ED, Zhu Y, Henderson RJ, Boyle NM, Leske DA, et al. At‐home visual acuity in children using a custom iPhone application compared with standardized in‐office visual acuity testing. Optometry and Vision Science. 2026;103(4). doi:10.1002/ovs2.70040

BibTeX
@article{Roberts2026,
  author = {Roberts, Tawna L and Bothun, Erick D and Zhu, Yufeng and Henderson, Robert J and Boyle, Nicole M and Leske, David A and Hatt, Sarah R and Wernimont, Suzanne M and Marino, Carrie E and Raghuram, Aparna and Manh, Vivian M and Youngerman, Jillian M and Qayum, Jennifer N and Srinivasan, Gayathri and Titelbaum, Jenna R and Crouch, Eric R and Colburn, Jeffrey D and Esposito, Christina A and Zeto, V Lori and Connolly, Katie S and Bhakta, Rita M and Lorenzana, Ingryd J and McDowell, Paula S and Beaulieu, Wesley T and Kraker, Raymond T and Holmes, Jonathan M and Pineles, Stacy L and Weise, Katherine K and Cotter, Susan A and Pediatric Eye Disease Investigator Group, Pediatric Eye Disease Investigator Group},
  title = {At‐home visual acuity in children using a custom iPhone application compared with standardized in‐office visual acuity testing},
  journal = {Optometry and Vision Science},
  year = {2026},
  volume = {103},
  number = {4},
  doi = {10.1002/ovs2.70040}
}
Kostenlos starten →