EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Using data from both eyes of participants: Evaluating the power and Type‐I error rates of common approaches to ocular data analysis via a simulation study

Verwendung von Daten aus beiden Augen von Teilnehmenden: Bewertung von Power und Fehler 1. Art gängiger Ansätze zur okulären Datenanalyse mittels Simulationsstudie

Morgan C Ollinger iD, Patricia M Cisarik, Meredith A Ray

Optometry and Vision Science · 2026-01 · 103 (1)

DOI: 10.1002/ovs2.70027 ↗

Auf einen Blick

Die Simulationsstudie verglich gängige Analyseansätze für Daten aus beiden Augen. Gemischte Modelle, ein Auge pro Person und Mittelung der Augen kontrollierten den Fehler 1. Art besser als die Annahme unabhängiger Augen.

Fragestellung

Wie gut kontrollieren gängige statistische Verfahren bei Daten aus beiden Augen den Fehler 1. Art und die Power?

Methode

Simulation mit kontinuierlichem Outcome, bivariatem und univariatem Prädiktor; Korrelation 0–0,9, Stichproben 50, 100 und 150; 2.000 Datensätze je Bedingung; lineare Regression, gemischte Modelle und GEE.

Ergebnisse

Gemischte Modelle, ein Auge pro Person und Mittelung kontrollierten den Fehler 1. Art bei 0,05. GEE erhöhten ihn leicht. Zwei Augen als unabhängig modelliert führten bis 0,194. Bei univariaten Prädiktoren war die Power ähnlich, bei bivariaten höher für gemischte Modelle und GEE.

Schlussfolgerung der Autor:innen

Gemischte Modelle und GEE schnitten bei bivariaten, korrelierten Prädiktoren am besten ab. Unabhängig behandelte korrelierte Messungen erhöhen Fehler 1. Art und führen zu irreführend hoher Power; dieser Ansatz sollte vermieden werden.

Kernaussagen

  • Fehler 1. Art bei 0,05: gut kontrolliert durch gemischte Modelle, ein Auge pro Person und Mittelung
  • Unabhängige Modellierung beider Augen: Fehler 1. Art bis 0,194
  • Bei bivariaten Prädiktoren: höhere Power für gemischte Modelle und GEE

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Optometry and Vision Science, online erschienen am 18.03.2026. Verfasst von Morgan C Ollinger und 2 weiteren Autor:innen. Beteiligte Einrichtung: Southern College of Optometry, Memphis, Tennessee, USA. Hauptthemen laut MEDLINE: Computer Simulation, Models, Statistical. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NEI NIH HHS.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study is to evaluate and quantify model performance for commonly used statistical approaches when using data from both eyes of participants. These models highlight different methods of accounting for interocular correlation.

Methods

We simulated a continuous outcome variable, a predictor variable measured per‐eye (two correlated values per subject – termed bivariate), and a predictor measured once per subject (termed univariate). Both the outcome and the bivariate predictor shared the same correlation level in all simulations. Correlations were varied 0–0.9 in 0.1 steps, with sample sizes of 50, 100, and 150. Two thousand datasets were simulated under each correlation‐sample size combination. The datasets were modeled using single‐eye, averaged‐eye, and assumed‐independent two‐eye approaches within linear regression, along with a mixed effects model and a generalized estimating equation (GEE).

Results

Mixed effects models, modeling one eye per subject, and averaging eyes within subjects all controlled Type‐I error at 0.05 across simulated conditions. GEEs slightly inflated Type‐I error, especially with smaller sample sizes. Modeling both eyes independently inflated Type‐I error as high as 0.194 in high correlation scenarios. This inflation increased with increasing correlation. For univariate predictors, GEEs, mixed effects modeling and averaging eyes within subjects attained similar power across scenarios. Single‐eye modeling resulted in lower power, particularly in low correlation scenarios. For bivariate predictors, mixed effects modeling and GEEs yielded greater power than single‐eye or averaged‐eye modeling across scenarios.

Conclusions

Mixed effects models and GEEs out‐perform other approaches when the predictor of interest is bivariate and correlated, assuming correlations are similar for the predictor and outcome. For univariate predictors, averaging the outcome across eyes within each subject performs similarly to mixed effects modeling. Treating correlated measurements as independent (such as when using data from both eyes without averaging or factored into a model) inflates Type‐I error rates and yields inappropriately high power, especially as correlation increases; this modeling approach leads to inference errors and should be avoided.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer SimulationModels, StatisticalHumans

Autor:innen und Institutionen

  • Southern College of Optometry, Memphis, Tennessee, USA.
  • University of Memphis, Memphis, Tennessee, USA.

ORCID-Profile: Morgan C Ollinger

Förderung

  • NEI NIH HHS

Zitieren

APA

Ollinger, M. C., Cisarik, P. M., & Ray, M. A. (2026). Using data from both eyes of participants: Evaluating the power and Type‐I error rates of common approaches to ocular data analysis via a simulation study. Optometry and Vision Science, 103(1). https://doi.org/10.1002/ovs2.70027

Vancouver

Ollinger MC, Cisarik PM, Ray MA. Using data from both eyes of participants: Evaluating the power and Type‐I error rates of common approaches to ocular data analysis via a simulation study. Optometry and Vision Science. 2026;103(1). doi:10.1002/ovs2.70027

BibTeX
@article{Ollinger2026,
  author = {Ollinger, Morgan C and Cisarik, Patricia M and Ray, Meredith A},
  title = {Using data from both eyes of participants: Evaluating the power and Type‐I error rates of common approaches to ocular data analysis via a simulation study},
  journal = {Optometry and Vision Science},
  year = {2026},
  volume = {103},
  number = {1},
  doi = {10.1002/ovs2.70027}
}
Kostenlos starten →