Core–Sheath Nanofibers From a Modified Coaxial Electrospinning for Transdermal Delivery of Finasteride
ChemistryOpen · 2026-06 · 15 (6)
DOI: 10.1002/open.202500564 ↗Kurz gefasst
Fachartikel in der Zeitschrift ChemistryOpen, online erschienen am 14.06.2026. Verfasst von Liang Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Nanofibers, Finasteride, Drug Delivery Systems. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 96 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Traditional blending electrospinning has a series of issues during implementation, and the corresponding monolithic nanofibers can always be updated through the intentional design of core–sheath nanostructures. In this study, a modified coaxial electrospinning approach was employed to refine the electrospinning process by eliminating abnormal phenomena, while simultaneously imparting core–sheath nanostructures and improved transdermal finasteride (FIN) delivery performance. Using an electrospinnable ethylcellulose (EC) solution containing FIN as the core fluid and an unspinnable polyvinylpyrrolidone (PVP)/sodium dodecyl sulfate (SDS) solution as the sheath fluid, medicated core–sheath nanofibers (E3) were fabricated continuously and robustly. The monolithic nanofibers (E2) from a conventional blending electrospinning were prepared as a comparison. FIN existed in an amorphous state within both E2 and E3 nanofibers, attributed to its excellent compatibility with EC. The sustained release profiles of nanofibers E2 and E3 are similar, but the penetration rates of FIN molecules from the nanofibers E2 and E3 always have significant differences from the initial tests at 0.5 h (10.32 ± 4.31% and 12.85 ± 5.14% for nanofibers E2 and E3, respectively) to the final tests at 4.0 h (38.16 ± 5.47% and 51.31 ± 5.19% for nanofibers E2 and E3, respectively). The mechanism underlying the robust preparation enabled by the unspinnable sheath fluid is proposed: it prevents multiple abnormal phenomena inherent to single‐fluid blending processes. This protocol offers a versatile strategy to upgrade traditional single‐fluid blending electrospinning products, endowing them with an improved functional performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Urology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China.
- Department of Urology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, China.
- School of Information Science and Technology, Sanda University, Shanghai, China.
- Department of Science and Education, Dongying People's Hospital (Dongying Hospital of Shandong Provincial Hospital Group), Dongying, China.
ORCID-Profile: Deng-Guang Yu
Zitieren
APA
Sun, L., Zhao, Y., Caomeng, X., Yu, D. G., & Liu, P. (2026). Core–Sheath Nanofibers From a Modified Coaxial Electrospinning for Transdermal Delivery of Finasteride. ChemistryOpen, 15(6). https://doi.org/10.1002/open.202500564
Vancouver
Sun L, Zhao Y, Caomeng X, Yu DG, Liu P. Core–Sheath Nanofibers From a Modified Coaxial Electrospinning for Transdermal Delivery of Finasteride. ChemistryOpen. 2026;15(6). doi:10.1002/open.202500564
BibTeX
@article{Sun2026,
author = {Sun, Liang and Zhao, Yisa and Caomeng, Xiyu and Yu, Deng-Guang and Liu, Ping},
title = {Core–Sheath Nanofibers From a Modified Coaxial Electrospinning for Transdermal Delivery of Finasteride},
journal = {ChemistryOpen},
year = {2026},
volume = {15},
number = {6},
doi = {10.1002/open.202500564}
}
EUVIMED