Efficacy of Oral Appliance for Mild, Moderate, and Severe Obstructive Sleep Apnea: A Meta‐analysis
Otolaryngology–Head and Neck Surgery · 2024-05 · 170 (5) · 1270-1279
DOI: 10.1002/ohn.676 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Otolaryngology–Head and Neck Surgery, online erschienen am 16.02.2024. Verfasst von Jianhong Liao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sleep Medical Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Severity of Illness Index, Mandibular Advancement. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 61 Literaturangaben.
Abstract (Originalsprache)
Objective
Oral appliances (OA) are the recommended first‐line option for mild‐to‐moderate obstructive sleep apnea (OSA)‐hypopnea. However, there is a lack of evidence to compare the effectiveness of OA in different severities of OSA. The purpose of this study was to investigate the therapeutic effects of preferred OA (tongue retention devices [TRD] and mandibular advancement device [MAD]) in different severities of OSA. Data Sources PubMed/MEDLINE, The Cochrane Library, and Web of Science. Review Methods Concentrating on the efficacy of OA, 2 authors searched 3 databases up to November 10, 2022, independently and systematically, following the requirements and steps of the Preferred Reporting Items for Systematic Reviews and Meta‐analyses guidelines.
Results
Ultimately, 42 studies with 2265 patients met the criteria for inclusion in OA. Overall, the apnea‐hypopnea index improved by 48% (5.6), 67% (14.92), and 62% (32.1) in mild, moderate, and severe OSA, respectively. Subgroup analysis showed a significant difference between MAD and TRD efficacy in mild OSA (58% vs 21%). However, no significant difference was seen between MAD and TRD efficacy in moderate (67% vs 66%) and severe OSA (66% vs 51%). There was no significant difference across groups in the Epworth Sleepiness Scale, oxygen desaturation index (ODI), and lowest oxygen saturation (LSAT).
Conclusion
Overall, both TRD and MAD are effective treatments for moderate and severe OSA. MAD is efficacious in mild OSA, while TRD requires further validation. Furthermore, mild‐moderate and severe OSA received similar improvements in sleepiness, ODI, and LSAT. This study complements the evidence for the efficacy of OA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Sleep Medical Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
- Obstructive Sleep Apnea-Hypopnea Syndrome Clinical Diagnosis and Therapy and Research Centre, Capital Medical University, Beijing, China.
- Key Laboratory of Otolaryngology, Head and Neck Surgery, Ministry of Education, Beijing, China.
- Xinjiang Key Laboratory of Biopharmaceuticals and Medical Devices, Xinjiang Medical University, Xinjiang, China.
ORCID-Profile: Jianhong Liao, Demin Han
Zitieren
APA
Liao, J., Shi, Y., Gao, X., Zhang, B., Li, Y., Xu, W., & Han, D. (2024). Efficacy of Oral Appliance for Mild, Moderate, and Severe Obstructive Sleep Apnea: A Meta‐analysis. Otolaryngology–Head and Neck Surgery, 170(5), 1270-1279. https://doi.org/10.1002/ohn.676
Vancouver
Liao J, Shi Y, Gao X, Zhang B, Li Y, Xu W, et al. Efficacy of Oral Appliance for Mild, Moderate, and Severe Obstructive Sleep Apnea: A Meta‐analysis. Otolaryngology–Head and Neck Surgery. 2024;170(5):1270-1279. doi:10.1002/ohn.676
BibTeX
@article{Liao2024,
author = {Liao, Jianhong and Shi, Yunhan and Gao, Xiang and Zhang, Bowen and Li, Yanru and Xu, Wen and Han, Demin},
title = {Efficacy of Oral Appliance for Mild, Moderate, and Severe Obstructive Sleep Apnea: A Meta‐analysis},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2024},
volume = {170},
number = {5},
pages = {1270--1279},
doi = {10.1002/ohn.676}
}
EUVIMED