EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preparation and Reliability and Validity Test of the Questionnaire on the Maintenance of Intravenous Catheter in ICU Nurses' Center

Feng Cheng iD, Hong Fu, Wei Yang

Nursing Open · 2025

DOI: 10.1002/nop2.70145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nursing Open, 2025. Verfasst von Feng Cheng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Critical Care Medicine, First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China. Hauptthemen laut MEDLINE: Psychometrics, Catheterization, Central Venous. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To compile a questionnaire Knowledge, Attitude and Practices (KAP) of ICU nurses on central venous catheter maintenance and test the reliability and validity of the questionnaire.

Design

Compile a questionnaire, conduct a questionnaire survey and test the reliability and validity of the questionnaire.

Methods

The initial questionnaire was formed based on the theory of KAP, combined with literature review and Delphi expert correspondence method; a questionnaire survey was conducted among 334 ICU nurses in five tertiary hospitals, and the reliability and validity of the questionnaire were tested and a formal questionnaire was compiled.

Results

The ICU nurses' CVC maintenance KAP questionnaire included 31 items in three dimensions of knowledge, attitude and behaviour. The item content validity (I‐CVI) and questionnaire content validity (S‐CVI) were 0.889 ~ 1.000 and 0.974, respectively. Exploratory factor analysis extracts three common factors (dimensions), the cumulative variance contribution rate is 65.656%, the Cronbach' α coefficient of the total questionnaire is 0.843, and the Cronbach's α coefficients of the three dimensions of KAP are 0.754, 0.887 and 0.940, respectively. The split‐half reliability is 0.816. The test–retest reliability of the total questionnaire is 0.813.

Conclusion

The ICU nurses' CVC maintenance KAP questionnaire has good reliability and validity, stable results, comprehensive coverage, and high feasibility. It can be used as a measurement tool to evaluate the maintenance level of CVC for ICU nurses in China. No Patient or Public Contribution No patient or public contribution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PsychometricsCatheterization, Central VenousHumansSurveys and QuestionnairesReproducibility of ResultsAdultFemaleMaleIntensive Care UnitsMiddle AgedDelphi TechniqueHealth Knowledge, Attitudes, PracticeChina

Autor:innen und Institutionen

  • Department of Critical Care Medicine, First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.

ORCID-Profile: Feng Cheng

Zitieren

APA

Cheng, F., Fu, H., & Yang, W. (2025). Preparation and Reliability and Validity Test of the Questionnaire on the Maintenance of Intravenous Catheter in ICU Nurses' Center. Nursing Open. https://doi.org/10.1002/nop2.70145

Vancouver

Cheng F, Fu H, Yang W. Preparation and Reliability and Validity Test of the Questionnaire on the Maintenance of Intravenous Catheter in ICU Nurses' Center. Nursing Open. 2025. doi:10.1002/nop2.70145

BibTeX
@article{Cheng2025,
  author = {Cheng, Feng and Fu, Hong and Yang, Wei},
  title = {Preparation and Reliability and Validity Test of the Questionnaire on the Maintenance of Intravenous Catheter in ICU Nurses' Center},
  journal = {Nursing Open},
  year = {2025},
  doi = {10.1002/nop2.70145}
}
Kostenlos starten →