MR Steal Phenomenon Corresponds to Cerebral Angiogram Circulation Time
Clinical Neuroimaging · 2025
DOI: 10.1002/neo2.70014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Neuroimaging, 2025. Verfasst von Ismail Rahim und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Cerebrovascular reserve (CVR) is crucial for assessing hemodynamic impairment in patients with cerebrovascular steno‐occlusive disease. Although catheter cerebral angiography is the gold standard for evaluating CVR and collateral circulation, acetazolamide‐challenged arterial spin labeling perfusion MRI (AC‐ASL) emerged as a non‐invasive alternative, but its effectiveness in reflecting neuroangiographic parameters is not fully understood.
Methods
A retrospective study was conducted on patients who underwent AC‐ASL from 2014–2022. Patients were excluded if concurrent angiographic analysis was not performed, or image quality was compromised. The study involved correlating cerebral angiographic metrics like arteriocapillary circulation time (ACCT) and superior sagittal sinus entry (SSSE) with AC‐ASL flow parameters in patients with steno‐occlusive disease. MR acquisitions were obtained prior to acetazolamide administration and after 1 g of acetazolamide administered at 5‐ and 10‐min intervals. Cerebral angiography was performed via a transfemoral approach utilizing a dual‐plane digital subtraction angiogram (DSA) radiographic angiographic system. CT angiograms were utilized if DSA was not available.
Results
The study included 32 patients, predominantly with unilateral disease. A significant correlation was found between AC‐ASL adjusted steal percent and angiographic ACCT ( ρ = −0.386, p = 0.035), which was stronger when comparing the ratio of ACCT (rACCT) between occlusive and nonocclusive hemispheres ( ρ = −0.4680, p = 0.008). No significant correlation was found between AC‐ASL and SSSE nor angiographic collateralization patterns.
Conclusion
AC‐ASL correlates with ACCT, comparable to catheter angiography in patients with steno‐occlusive disease, with a weak‐moderate coefficient. AC‐ASL may be useful for the assessment of CVR in patients, providing a safe and non‐invasive adjunct to assessing CVR.
Zitieren
APA
Rahim, I., Denes, S., George, D., Timothy, H., Schartz, D., Manganaro, M., Bender, M., & Wang, H. (2025). MR Steal Phenomenon Corresponds to Cerebral Angiogram Circulation Time. Clinical Neuroimaging. https://doi.org/10.1002/neo2.70014
Vancouver
Rahim I, Denes S, George D, Timothy H, Schartz D, Manganaro M, et al. MR Steal Phenomenon Corresponds to Cerebral Angiogram Circulation Time. Clinical Neuroimaging. 2025. doi:10.1002/neo2.70014
BibTeX
@article{Rahim2025,
author = {Rahim, Ismail and Denes, Szekeres and George, Derek and Timothy, Hoang and Schartz, Derrek and Manganaro, Mark and Bender, Matthew and Wang, Henry},
title = {MR Steal Phenomenon Corresponds to Cerebral Angiogram Circulation Time},
journal = {Clinical Neuroimaging},
year = {2025},
doi = {10.1002/neo2.70014}
}