Bar code scanning of ready‐to‐feed enteral nutrition formulas improves patient safety and reduces risk of misadministration in pediatric patients ages 1–18: A quality improvement project in a single children's hospital

Caroline Steele iD, Desiree Albert

Nutrition in Clinical Practice · 2025

DOI: 10.1002/ncp.70003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nutrition in Clinical Practice, 2025. Verfasst von Caroline Steele und 1 weiteren Autor:innen. Beteiligte Einrichtung: Timeless Medical Systems, New Port Richey, FL, USA. Hauptthemen laut MEDLINE: Enteral Nutrition, Quality Improvement, Food, Formulated, Patient Safety. Die Arbeit nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The safe use of enteral nutrition (EN) for patients of all ages in the healthcare setting is often taken for granted. However, an increasing body of literature highlights potential failure points even when using ready‐to‐feed (RTF) enteral formulas. Potential risks include administering a wrong, expired, or recalled formula which could result in patient harm including under or over nutrition, allergic reactions, gastrointestinal intolerance, metabolic or electrolyte disturbances, and/or consequences related to contamination. This quality improvement project reviewed the frequency of having the wrong RTF EN formula scanned for the wrong individual (defined as a near miss) in pediatric patients 1–18 years of age. During the time of this evaluation, a total of 48,044 RTF EN formula feeding attempts were recorded. Of those attempts, 46,648 were successful, with the RTF EN formula matching the patient's EN order when the patient's armband and EN bar code were scanned. The remaining 1396 attempts represented near misses in which the product being scanned was not the correct product for the patient (a rate of 2.9%). Although this rate may seem low, the number of near misses during this time frame means that, on average, 48 times per month or 1.6 times per day, the bar code scanning system is preventing a pediatric patient from receiving the wrong EN formula. The data from this performance improvement initiative support the organization's decision to scan EN formulas at the time of administration and underscores the importance of following protocols to ensure that scanning occurs every time when administering formulas to reduce risk of error.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Enteral NutritionQuality ImprovementFood, FormulatedPatient SafetyMedication ErrorsHumansInfantChildAdolescentChild, PreschoolHospitals, Pediatric

Stichwörter der Autor:innen

enteral formulasenteral nutritionnutrition support practiceoutcomes research/qualitypatient safetypediatricstechnology

Autor:innen und Institutionen

  • Timeless Medical Systems, New Port Richey, FL, USA.
  • Formula, Human Milk, and Patient Dining, Stanford Medicine Children's Health, Palo Alto, California, USA.

ORCID-Profile: Caroline Steele

Zitieren

APA

Steele, C., & Albert, D. (2025). Bar code scanning of ready‐to‐feed enteral nutrition formulas improves patient safety and reduces risk of misadministration in pediatric patients ages 1–18: A quality improvement project in a single children's hospital. Nutrition in Clinical Practice. https://doi.org/10.1002/ncp.70003

Vancouver

Steele C, Albert D. Bar code scanning of ready‐to‐feed enteral nutrition formulas improves patient safety and reduces risk of misadministration in pediatric patients ages 1–18: A quality improvement project in a single children's hospital. Nutrition in Clinical Practice. 2025. doi:10.1002/ncp.70003

BibTeX
@article{Steele2025,
  author = {Steele, Caroline and Albert, Desiree},
  title = {Bar code scanning of ready‐to‐feed enteral nutrition formulas improves patient safety and reduces risk of misadministration in pediatric patients ages 1–18: A quality improvement project in a single children's hospital},
  journal = {Nutrition in Clinical Practice},
  year = {2025},
  doi = {10.1002/ncp.70003}
}