EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validation of a Novel, Low‐Cost, Portable MRI‐Compatible Exercise Device in Healthy Volunteers and Patients With Pulmonary Hypertension

Ruta Virsinskaite iD, James T Brown iD, Tushar Kotecha, Darren Bower, Jennifer A Steeden iD, Javier Montalt-Tordera, Olivier Jaubert iD, Marianna Fontana, J Gerry Coghlan iD, Daniel S Knight iD, Vivek Muthurangu iD

NMR in Biomedicine · 2026

DOI: 10.1002/nbm.70412 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Ruta Virsinskaite und 10 weiteren Autor:innen. Beteiligte Einrichtung: National Pulmonary Hypertension Service, Royal Free London NHS Foundation Trust, London, UK. Hauptthemen laut MEDLINE: Hypertension, Pulmonary, Magnetic Resonance Imaging, Exercise Test, Healthy Volunteers. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation (BHF) Clinical Research Leave Fellowship, National Institute for Health Research (NIHR) University College London Hospitals (UCLH) Biomedical Research Centre (BRC), BHF Intermediate Fellowship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The value of exercise cardiovascular magnetic resonance (CMR) has been shown in many clinical scenarios. We have developed a novel MR‐compatible exercise device and aim to validate it against the reference standard MR‐conventional ergometer. The novel device consisted of two half‐pipes fixed to a wooden base, with participants wearing knee‐length socks with a 0.5 kg weight in each sock. Increased workload was achieved by increasing the rate of alternating leg flexion and extension in time with a bleep sound of increasing frequency. Twenty subjects (10 healthy volunteers, 10 patients with pulmonary arterial hypertension) performed two CMR‐augmented cardiopulmonary exercise tests (CMR/CPET) using the novel exercise device and a conventional ergometer in a randomised order. Comparing peak metrics elicited on both exercise devices, there was a moderate correlation in peak oxygen consumption (VO 2 , r = 0.86, p < 0.001), cardiac output (CO, r = 0.73, p < 0.001), stroke volume (SV, r = 0.90, p < 0.001), peak heart rate (HR, r = 0.65, p = 0.002) and peak arteriovenous oxygen content gradient (ΔavO 2 , r = 0.71, p < 0.001). However, all metrics were significantly lower with the novel device. Both devices were able to elicit statistically significant differences in VO 2 , HR and right ventricular ejection fraction (RVEF) between patients and healthy subjects ( p ≤ 0.04). We have created a simple, easy to use and affordable exercise device for the CMR environment. This may encourage greater dissemination of exercise CMR in clinical and research practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypertension, PulmonaryMagnetic Resonance ImagingExercise TestHealthy VolunteersExerciseHumansMaleFemaleAdultMiddle AgedReproducibility of Results

Stichwörter der Autor:innen

exercise CMR devicepulmonary hypertensionsystemic sclerosis

Autor:innen und Institutionen

  • National Pulmonary Hypertension Service, Royal Free London NHS Foundation Trust, London, UK.
  • Department of Cardiac MRI, Royal Free London NHS Foundation Trust, London, UK.
  • Institute of Cardiovascular Science, University College London, London, UK.
  • Engineering Department, Royal Free London NHS Foundation Trust, London, UK.
  • Division of Medicine, University College London, London, UK.

ORCID-Profile: Ruta Virsinskaite, James T Brown, Jennifer A Steeden, Olivier Jaubert, J Gerry Coghlan, Daniel S Knight, Vivek Muthurangu

Förderung

  • British Heart Foundation (BHF) Clinical Research Leave Fellowship
  • National Institute for Health Research (NIHR) University College London Hospitals (UCLH) Biomedical Research Centre (BRC)
  • BHF Intermediate Fellowship

Zitieren

APA

Virsinskaite, R., Brown, J. T., Kotecha, T., Bower, D., Steeden, J. A., Montalt-Tordera, J., Jaubert, O., Fontana, M., Coghlan, J. G., Knight, D. S., & Muthurangu, V. (2026). Validation of a Novel, Low‐Cost, Portable MRI‐Compatible Exercise Device in Healthy Volunteers and Patients With Pulmonary Hypertension. NMR in Biomedicine. https://doi.org/10.1002/nbm.70412

Vancouver

Virsinskaite R, Brown JT, Kotecha T, Bower D, Steeden JA, Montalt-Tordera J, et al. Validation of a Novel, Low‐Cost, Portable MRI‐Compatible Exercise Device in Healthy Volunteers and Patients With Pulmonary Hypertension. NMR in Biomedicine. 2026. doi:10.1002/nbm.70412

BibTeX
@article{Virsinskaite2026,
  author = {Virsinskaite, Ruta and Brown, James T and Kotecha, Tushar and Bower, Darren and Steeden, Jennifer A and Montalt-Tordera, Javier and Jaubert, Olivier and Fontana, Marianna and Coghlan, J Gerry and Knight, Daniel S and Muthurangu, Vivek},
  title = {Validation of a Novel, Low‐Cost, Portable MRI‐Compatible Exercise Device in Healthy Volunteers and Patients With Pulmonary Hypertension},
  journal = {NMR in Biomedicine},
  year = {2026},
  doi = {10.1002/nbm.70412}
}
Kostenlos starten →