Klinische Studie in der Zeitschrift NMR in Biomedicine, online erschienen am 23.06.2026. Verfasst von Guillaume Paillart und 7 weiteren Autor:innen. Beteiligte Einrichtung: IADI (U1254), Université de Lorraine and Inserm, Nancy, France. Hauptthemen laut MEDLINE: Brain, Electric Conductivity, Magnetic Resonance Imaging, Radio Waves. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ELECTRA project, CPER IT2MP, European Regional Development Fund.
Abstract (Originalsprache)
Tissue electrical properties are required by electromagnetic simulation software to conduct radiofrequency (RF) safety studies. Values are commonly taken from existing databases of tissue properties, where brain conductivity was measured ex vivo. We hypothesize that using in vivo brain conductivity values, as reported in the recent literature on in vivo MRI measurements, can improve the accuracy of such simulations. Sixteen subjects were scanned at 3T to obtain experimental maps of the transmit RF field, , of the head. Electromagnetic simulations were performed using biomodels with varying morphologies, using both a conventional () and a modified brain conductivity (). A framework was developed to process the simulated fields, including a systematic method to combine the two excitation ports of the transmit coil model (accounting for different load impedances between simulation and experiment), geometric alignment, and scaling of the simulated fields, allowing a quantitative comparison of complex maps of the brain with experimental maps. Specific absorption rate (SAR) maps were also estimated by different methods, including a novel ‐derived formula. Normalized root‐mean‐squared errors between simulation and experiment, in the brain, were approximately 6% for magnitude. While head geometry mainly impacted the accuracy of magnitude, with errors up to 11% ( p = 0.007) between the best fitting human model and the worst one, brain electrical conductivity mainly impacted phase, with errors reduced by 48% when using instead of ( p = 0.0004). The agreement in average brain SAR, between simulation and experiment, was also improved, with differences reduced from 62% () to 22% (). Using brain conductivity values from recent in vivo studies improves the accuracy of RF safety modelling. Trial Registration ClinicalTrials.gov identifier: NCT04645628.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- IADI (U1254), Université de Lorraine and Inserm, Nancy, France.
- ICube (UMR 7357), University of Strasbourg and CNRS, Strasbourg, France.
- Healtis, Nancy, France.
- Siemens Healthcare SAS, Courbevoie, France.
- CIC-IT 1433, Inserm, Université de Lorraine and CHRU Nancy, Nancy, France.
ORCID-Profile: Guillaume Paillart
Förderung
- ELECTRA project
- CPER IT2MP
- European Regional Development Fund
- France Life Imaging
Zitieren
APA
Paillart, G., He, Z., Romero, G., Ferry, P., Ambarki, K., Soullié, P., Felblinger, J., & Odille, F. (2026). Improved Radiofrequency Safety Modelling in MRI Using In Vivo Measurements of Brain Conductivity. NMR in Biomedicine, 39(8). https://doi.org/10.1002/nbm.70335
Vancouver
Paillart G, He Z, Romero G, Ferry P, Ambarki K, Soullié P, et al. Improved Radiofrequency Safety Modelling in MRI Using In Vivo Measurements of Brain Conductivity. NMR in Biomedicine. 2026;39(8). doi:10.1002/nbm.70335
BibTeX
@article{Paillart2026,
author = {Paillart, Guillaume and He, Zhongzheng and Romero, Grecia and Ferry, Pauline and Ambarki, Khalid and Soullié, Paul and Felblinger, Jacques and Odille, Freddy},
title = {Improved Radiofrequency Safety Modelling in MRI Using In Vivo Measurements of Brain Conductivity},
journal = {NMR in Biomedicine},
year = {2026},
volume = {39},
number = {8},
doi = {10.1002/nbm.70335}
}
EUVIMED