Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence
NMR in Biomedicine · 2026-05 · 39 (5)
DOI: 10.1002/nbm.70281 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 06.04.2026. Verfasst von Jens H Jensen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA. Hauptthemen laut MEDLINE: Monte Carlo Method, Water, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIA NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Intercompartmental water exchange in brain and other biological tissue can be probed in vivo with diffusion MRI (dMRI). We assess the accuracy of a recently proposed method for estimating a mean exchange rate by performing Monte Carlo simulations of random walkers through a packing of permeable, randomly placed, parallel cylinders to model water exchange within axonal fiber bundles. The diffusivity and kurtosis of the full system are calculated for a broad range of diffusion times and model parameters. The mean exchange rate is estimated from the logarithmic derivative of the kurtosis with respect to the diffusion time and compared with the exchange rate predicted by the Kärger model (KM), which is exact in certain limits. The mean exchange rate is also compared with the reciprocal exchange time obtained by conventional fitting of the kurtosis time dependence to a two‐compartment KM, with a high correlation being found between the two quantities. The estimates from the logarithmic derivative are in good agreement with the KM predictions when the exchange time is long in comparison to the compartment traversal times, which corresponds to barrier‐limited exchange. Compared to the standard procedure of fitting the kurtosis to the KM over a broad range of diffusion times, using the logarithmic derivative reduces the data acquisition burden by only requiring a narrow range of times and increases generality in that number of compartments need not be specified. This method may be useful for estimating the mean exchange rate from the kurtosis time dependence measured with dMRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA.
- Department of Neuroscience, Medical University of South Carolina, Charleston, South Carolina, USA.
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina, USA.
- Department of Radiology, New York University School of Medicine, New York, New York, USA.
ORCID-Profile: Jens H Jensen, Els Fieremans
Förderung
- NIA NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Jensen, J. H., Coronado-Leija, R., & Fieremans, E. (2026). Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence. NMR in Biomedicine, 39(5). https://doi.org/10.1002/nbm.70281
Vancouver
Jensen JH, Coronado-Leija R, Fieremans E. Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence. NMR in Biomedicine. 2026;39(5). doi:10.1002/nbm.70281
BibTeX
@article{Jensen2026,
author = {Jensen, Jens H and Coronado-Leija, Ricardo and Fieremans, Els},
title = {Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence},
journal = {NMR in Biomedicine},
year = {2026},
volume = {39},
number = {5},
doi = {10.1002/nbm.70281}
}
EUVIMED