Feasibility of High‐Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T

Fabian Niess iD, Bernhard Strasser, Lukas Hingerl, Johannes J Kovarik, Viola Bader iD, Sabina Frese, Anna Duguid, Aaron Osburg, Eva Niess iD, Stanislav Motyka iD, Martin Krššák, Thomas Scherer und 1 weitere

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70139 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Fabian Niess und 12 weiteren Autor:innen. Beteiligte Einrichtung: High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Kidney, Deuterium, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund, NIBIB NIH HHS, European Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The human kidneys play a pivotal role in regulating blood pressure, water, and salt homeostasis, but assessment of renal function typically requires invasive methods. Deuterium metabolic imaging (DMI) is a novel, noninvasive technique for mapping tissue‐specific uptake and metabolism of deuterium‐labeled tracers. This study evaluates the feasibility of renal DMI at 7‐Tesla (7T) to track deuterium‐labeled tracers with high spatial and temporal resolution, aiming to establish a foundation for potential clinical applications in the noninvasive investigation of renal physiology and pathophysiology. Five healthy participants (3 m/2f) underwent renal DMI at 7T using MR spectroscopic imaging with concentric ring trajectory sampling. Two subjects participated in dynamic DMI experiments after oral administration of deuterium‐labeled water (D 2 O, 0.25, and 0.5 mL/kg) or glucose ([6,6′‐ 2 H]‐Glc, 0.5 g/kg) following 12 h overnight fasting. Continuous glucose monitoring (CGM) was performed using FreeStyle Libre 3 and compared to renal 2 H‐glucose levels. Three‐dimensional maps of 2 H‐water and 2 H‐glucose were acquired every ∼8.5 min at isotropic resolutions of ∼1.8 and ∼0.9 mL, respectively. Tensor Marchenko‐Pastur Principal Component Analysis (tMPPCA) was used for spectral denoising. Renal DMI successfully generated dynamic 3D maps of 2 H‐water and 2 H‐glucose with improved spatial resolution compared to previous studies. Following D 2 O ingestion, 2 H‐water dynamics (0‐60 min) and steady‐state levels (> 90 min) were assessed. Following 2 H‐glucose ingestion, renal 2 H‐Glc concentrations peaked at 1.8 ± 1.0 mM on average over both kidneys, and overall dynamics aligned with interstitial glucose levels simultaneously assessed using CGM sensor. This study demonstrates the feasibility of dynamic renal DMI with improved spatial resolution to noninvasively map multiple 2 H‐labeled tracers in the human kidney at 7T. Future improvements in signal mitigation and intravenous tracer administration could enhance its clinical utility, potentially aiding in the evaluation of metabolic effects of novel therapies like SGLT‐2 inhibitors for personalized treatment strategies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KidneyDeuteriumMagnetic Resonance ImagingHumansFeasibility StudiesMaleAdultFemaleGlucose

Stichwörter der Autor:innen

3D magnetic resonance spectroscopic imagingDMIdeuterium labeled glucosedeuterium labeled waterdeuterium metabolic imagingkidney imaging

Substanzen

DeuteriumGlucose

Autor:innen und Institutionen

  • High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Clinical Division of Internal Medicine III Department of Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria.
  • Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Clinical Division of Internal Medicine III Department of Endocrinology and Metabolism, Medical University of Vienna, Vienna, Austria.

ORCID-Profile: Fabian Niess, Viola Bader, Eva Niess, Stanislav Motyka, Wolfgang Bogner

Förderung

  • Austrian Science Fund
  • NIBIB NIH HHS
  • European Commission
  • NIH HHS
  • Christian Doppler Lab
  • National Institutes of Health

Zitieren

APA

Niess, F., Strasser, B., Hingerl, L., Kovarik, J. J., Bader, V., Frese, S., Duguid, A., Osburg, A., Niess, E., Motyka, S., Krššák, M., Scherer, T., & Bogner, W. (2025). Feasibility of High‐Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T. NMR in Biomedicine. https://doi.org/10.1002/nbm.70139

Vancouver

Niess F, Strasser B, Hingerl L, Kovarik JJ, Bader V, Frese S, et al. Feasibility of High‐Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T. NMR in Biomedicine. 2025. doi:10.1002/nbm.70139

BibTeX
@article{Niess2025,
  author = {Niess, Fabian and Strasser, Bernhard and Hingerl, Lukas and Kovarik, Johannes J and Bader, Viola and Frese, Sabina and Duguid, Anna and Osburg, Aaron and Niess, Eva and Motyka, Stanislav and Krššák, Martin and Scherer, Thomas and Bogner, Wolfgang},
  title = {Feasibility of High‐Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70139}
}
Kostenlos starten →